» Articles » PMID: 32998452

Fuzzy-Inspired Photoplethysmography Signal Classification with Bio-Inspired Optimization for Analyzing Cardiovascular Disorders

Overview
Specialty Radiology
Date 2020 Oct 1
PMID 32998452
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The main aim of this paper is to optimize the output of diagnosis of Cardiovascular Disorders (CVD) in Photoplethysmography (PPG) signals by utilizing a fuzzy-based approach with classification. The extracted parameters such as Energy, Variance, Approximate Entropy (ApEn), Mean, Standard Deviation (STD), Skewness, Kurtosis, and Peak Maximum are obtained initially from the PPG signals, and based on these extracted parameters, the fuzzy techniques are incorporated to model the Cardiovascular Disorder(CVD) risk levels from PPG signals. Optimization algorithms such as Differential Search (DS), Shuffled Frog Leaping Algorithm (SFLA), Wolf Search (WS), and Animal Migration Optimization (AMO) are implemented to the fuzzy modeled levels to optimize them further so that the PPG cardiovascular classification can be characterized well. This kind of approach is totally new in PPG signal classification, and the results show that when fuzzy-inspired modeling is implemented with WS optimization and classified with the Radial Basis Function (RBF) classifier, a classification accuracy of 94.79% is obtained for normal cases. When fuzzy-inspired modeling is implemented with AMO and classified with the Support Vector Machine-Radial Basis Function (SVM-RBF) classifier, a classification accuracy of 95.05% is obtained for CVD cases.

Citing Articles

Leveraging Classifier Performance Using Heuristic Optimization for Detecting Cardiovascular Disease from PPG Signals.

Palanisamy S, Rajaguru H Diagnostics (Basel). 2024; 14(20).

PMID: 39451610 PMC: 11507182. DOI: 10.3390/diagnostics14202287.


Analysis of the Chaotic Component of Photoplethysmography and Its Association with Hemodynamic Parameters.

Xing X, Dong W, Xiao R, Song M, Jiang C Entropy (Basel). 2023; 25(12).

PMID: 38136462 PMC: 10742563. DOI: 10.3390/e25121582.


Machine Learning Techniques for the Performance Enhancement of Multiple Classifiers in the Detection of Cardiovascular Disease from PPG Signals.

Palanisamy S, Rajaguru H Bioengineering (Basel). 2023; 10(6).

PMID: 37370609 PMC: 10294971. DOI: 10.3390/bioengineering10060678.


A Framework on Performance Analysis of Mathematical Model-Based Classifiers in Detection of Epileptic Seizure from EEG Signals with Efficient Feature Selection.

Hemachandira V, Viswanathan R J Healthc Eng. 2022; 2022:7654666.

PMID: 36110984 PMC: 9470336. DOI: 10.1155/2022/7654666.


Research on recognition and classification of pulse signal features based on EPNCC.

Chen H, Guo C, Wang Z, Wang J Sci Rep. 2022; 12(1):6731.

PMID: 35468925 PMC: 9039079. DOI: 10.1038/s41598-022-10808-6.


References
1.
Karlen W, Kobayashi K, Ansermino J, Dumont G . Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation. Physiol Meas. 2012; 33(10):1617-29. DOI: 10.1088/0967-3334/33/10/1617. View

2.
Clarenbach C, Stoewhas A, van Gestel A, Latshang T, Lo Cascio C, Bloch K . Comparison of photoplethysmographic and arterial tonometry-derived indices of arterial stiffness. Hypertens Res. 2011; 35(2):228-33. DOI: 10.1038/hr.2011.168. View

3.
Otsuka T, Kawada T, Katsumata M, Ibuki C . Utility of second derivative of the finger photoplethysmogram for the estimation of the risk of coronary heart disease in the general population. Circ J. 2006; 70(3):304-10. DOI: 10.1253/circj.70.304. View

4.
Shin H, Min S . Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study. Biomed Eng Online. 2017; 16(1):10. PMC: 5234121. DOI: 10.1186/s12938-016-0302-y. View

5.
Suzuki T, Kameyama K, Tamura T . Development of the irregular pulse detection method in daily life using wearable photoplethysmographic sensor. Annu Int Conf IEEE Eng Med Biol Soc. 2009; 2009:6080-3. DOI: 10.1109/IEMBS.2009.5335401. View