» Articles » PMID: 32998221

Evaluation of Root-End Preparation with Two Different Endodontic Microsurgery Ultrasonic Tips

Overview
Journal Biomedicines
Date 2020 Oct 1
PMID 32998221
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study is to compare root-end preparation performed with two different ultrasonic tips-CVDentus and NSK-and respective time requirements. After root-end resection, 32 teeth were randomly divided in two groups, according to the ultrasonic tip used for root-end preparation. Preparation time was recorded. Photomicrographs were taken to assess the following parameters: root surface microcracking, marginal integrity and presence of debris. One ultrasonic tip from each group was analyzed through scanning electron microscopy before and after root-end preparation. The significance level was set at α = 0.05. Incidence of microcracks in both groups was 12.5%. Solely intracanal microcracking was found, consistently positioned within the widest side of the remaining dentine. No statistically significant differences were verified between both experimental groups regarding marginal integrity ( = 0.102) and preparation time ( = 0.780), whereas statistical differences ( = 0.003) were found concerning the presence of debris (the minimum registered score was mostly verified in CVDentus group). NSK tips showed major morphological changes, with extensive surface wear and noticeable loss of particles, which was not verified on CVDentus tips. Our findings suggest significant differences regarding root-end preparation walls quality, with CVDentus tips showing better results. Concerning microcracking, as well as preparation time and marginal integrity, both ultrasonic tips showed similar results. Qualitative analysis exposed NSK tips major morphological changes and wear after use, which was not verified on CVDentus tips.

Citing Articles

Metronidazole-laden silk fibroin methacrylated scaffolds for managing periapical lesions.

Silverberg A, Cardoso L, de Carvalho A, Dos Reis-Prado A, Fenno J, Dal-Fabbro R Odontology. 2024; .

PMID: 39523223 DOI: 10.1007/s10266-024-01023-y.


Evaluation of Dentinal Microcracks following Diode Laser- and Ultrasonic-Activated Removal of Bioceramic Material during Root Canal Retreatment.

Barakat R, Almohareb R, Alsayyar A, Almalki F, Alharbi H Scanning. 2022; 2022:6319743.

PMID: 36570434 PMC: 9705085. DOI: 10.1155/2022/6319743.


Guided Endodontics: Static vs. Dynamic Computer-Aided Techniques-A Literature Review.

Ribeiro D, Reis E, Marques J, Falacho R, Palma P J Pers Med. 2022; 12(9).

PMID: 36143301 PMC: 9501573. DOI: 10.3390/jpm12091516.


Intentional Replantation as a Starting Approach for a Multidisciplinary Treatment of a Mandibular Second Molar: A Case Report.

Santos J, Marques J, Esteves M, Sousa V, Palma P, Matos S J Clin Med. 2022; 11(17).

PMID: 36079036 PMC: 9457313. DOI: 10.3390/jcm11175111.


Models for Oral Biology Research.

Capela E Silva F, Lamy E, Castelo P Biomedicines. 2022; 10(5).

PMID: 35625688 PMC: 9138227. DOI: 10.3390/biomedicines10050952.


References
1.
Layton C, Marshall J, Morgan L, Baumgartner J . Evaluation of cracks associated with ultrasonic root-end preparation. J Endod. 1996; 22(4):157-60. DOI: 10.1016/S0099-2399(96)80091-4. View

2.
Berbert F, de Faria-Junior N, Tanomaru-Filho M, Guerreiro-Tanomaru J, Bonetti-Filho I, de Toledo Leonardo R . An in vitro evaluation of apicoectomies and retropreparations using different methods. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010; 110(4):e57-63. DOI: 10.1016/j.tripleo.2010.03.004. View

3.
Bernardes R, de Moraes I, Garcia R, Bernardineli N, Baldi J, Victorino F . Evaluation of apical cavity preparation with a new type of ultrasonic diamond tip. J Endod. 2007; 33(4):484-7. DOI: 10.1016/j.joen.2006.12.019. View

4.
de Lange J, Putters T, Baas E, van Ingen J . Ultrasonic root-end preparation in apical surgery: a prospective randomized study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007; 104(6):841-5. DOI: 10.1016/j.tripleo.2007.06.023. View

5.
Bernardes R, de Souza Junior J, Duarte M, de Moraes I, Bramante C . Ultrasonic chemical vapor deposition-coated tip versus high- and low-speed carbide burs for apicoectomy: time required for resection and scanning electron microscopy analysis of the root-end surfaces. J Endod. 2009; 35(2):265-8. DOI: 10.1016/j.joen.2008.11.009. View