» Articles » PMID: 32994483

A Lectin-coupled Porous Silicon-based Biosensor: Label-free Optical Detection of Bacteria in a Real-time Mode

Overview
Journal Sci Rep
Specialty Science
Date 2020 Sep 30
PMID 32994483
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Accuracy and speed of detection, along with technical and instrumental simplicity, are indispensable for the bacterial detection methods. Porous silicon (PSi) has unique optical and chemical properties which makes it a good candidate for biosensing applications. On the other hand, lectins have specific carbohydrate-binding properties and are inexpensive compared to popular antibodies. We propose a lectin-conjugated PSi-based biosensor for label-free and real-time detection of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) by reflectometric interference Fourier transform spectroscopy (RIFTS). We modified meso-PSiO (10-40 nm pore diameter) with three lectins of ConA (Concanavalin A), WGA (Wheat Germ Agglutinin), and UEA (Ulex europaeus agglutinin) with various carbohydrate specificities, as bioreceptor. The results showed that ConA and WGA have the highest binding affinity for E. coli and S. aureus respectively and hence can effectively detect them. This was confirmed by 6.8% and 7.8% decrease in peak amplitude of fast Fourier transform (FFT) spectra (at 10 cells mL concentration). A limit of detection (LOD) of about 10 cells mL and a linear response range of 10 to 10 cells mL were observed for both ConA-E. coli and WGA-S. aureus interaction platforms that are comparable to the other reports in the literature. Dissimilar response patterns among lectins can be attributed to the different bacterial cell wall structures. Further assessments were carried out by applying the biosensor for the detection of Klebsiella aerogenes and Bacillus subtilis bacteria. The overall obtained results reinforced the conjecture that the WGA and ConA have a stronger interaction with Gram-positive and Gram-negative bacteria, respectively. Therefore, it seems that specific lectins can be suggested for bacterial Gram-typing or even serotyping. These observations were confirmed by the principal component analysis (PCA) model.

Citing Articles

Real-Time Detection of Human Growth Hormone Based on Nanoporous Anodic Alumina Interferometric Biosensor.

Cantons J, Acosta L, Formentin P, Ferre-Borrull J, Bachhuka A, Marsal L Sensors (Basel). 2025; 25(4).

PMID: 40006250 PMC: 11859889. DOI: 10.3390/s25041021.


Silicon-Based Biosensors: A Critical Review of Silicon's Role in Enhancing Biosensing Performance.

Muhammad W, Song J, Kim S, Ahmed F, Cho E, Lee H Biosensors (Basel). 2025; 15(2).

PMID: 39997021 PMC: 11852904. DOI: 10.3390/bios15020119.


A comprehensive review of transduction methods of lectin-based biosensors in biomedical applications.

Pham T, Nguyen S, Tran M Heliyon. 2024; 10(19):e38371.

PMID: 39386779 PMC: 11462017. DOI: 10.1016/j.heliyon.2024.e38371.


Medical Relevance, State-of-the-Art and Perspectives of "Sweet Metacode" in Liquid Biopsy Approaches.

Pinkeova A, Kosutova N, Jane E, Lorencova L, Bertokova A, Bertok T Diagnostics (Basel). 2024; 14(7).

PMID: 38611626 PMC: 11011756. DOI: 10.3390/diagnostics14070713.


Design of a Porous Silicon Biosensor: Characterization, Modeling, and Application to the Indirect Detection of Bacteria.

Vercauteren R, Gevers C, Mahillon J, Francis L Biosensors (Basel). 2024; 14(2).

PMID: 38392023 PMC: 10886929. DOI: 10.3390/bios14020104.


References
1.
Taheri R, Rezayan A, Rahimi F, Mohammadnejad J, Kamali M . Development of an immunosensor using oriented immobilized anti-OmpW for sensitive detection of Vibrio cholerae by surface plasmon resonance. Biosens Bioelectron. 2016; 86:484-488. DOI: 10.1016/j.bios.2016.07.006. View

2.
Dhanekar S, Jain S . Porous silicon biosensor: current status. Biosens Bioelectron. 2012; 41:54-64. DOI: 10.1016/j.bios.2012.09.045. View

3.
Makiyan F, Rahimi F, Hajati M, Shafiekhani A, Rezayan A, Ansari-Pour N . Label-free discrimination of single nucleotide changes in DNA by reflectometric interference Fourier transform spectroscopy. Colloids Surf B Biointerfaces. 2019; 181:714-720. DOI: 10.1016/j.colsurfb.2019.05.066. View

4.
Pace S, Seantier B, Belamie E, Lautredou N, Sailor M, Milhiet P . Characterization of phospholipid bilayer formation on a thin film of porous SiO2 by reflective interferometric Fourier transform spectroscopy (RIFTS). Langmuir. 2012; 28(17):6960-9. DOI: 10.1021/la301085t. View

5.
Anglin E, Cheng L, Freeman W, Sailor M . Porous silicon in drug delivery devices and materials. Adv Drug Deliv Rev. 2008; 60(11):1266-1277. PMC: 2710886. DOI: 10.1016/j.addr.2008.03.017. View