» Articles » PMID: 32980330

Transcatheter Aortic Valve Implantation With J-Valve: 2-Year Outcomes From a Multicenter Study

Overview
Journal Ann Thorac Surg
Publisher Elsevier
Date 2020 Sep 27
PMID 32980330
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Background: We report the 2-year follow-up outcomes of the J-Valve in the treatment of either aortic stenosis (AS) or pure aortic insufficiency (AI) from a multicenter study.

Methods: From March 2014 to October 2016, 107 patients with either AS (n = 63) or pure AI (n = 44) were enrolled in a trial and were treated by transcatheter aortic valve implantation with the J-Valve system. All patients except 1 completed a 2-year clinical and echocardiographic follow-up (follow-up rate of 99%). The procedural and clinical outcomes were presented according to Valve Academic Research Consortium-2 criteria.

Results: The success rate of the device was 91.5%. All-cause mortality was 4.7% and 10.3% at 30 days and 2 years, respectively. Echocardiographic follow-up showed mild prosthetic valve regurgitation in 1.0% and 6.8% of patients at 30 days and 2 years, respectively. No patient showed more than mild aortic prosthetic regurgitation. At the 2-year follow-up, 97.6% of patients had mild or less than mild paravalvular leak and 99.8% of patients experienced notable improvement in heart failure symptoms (at least 1 NYHA level reduction). We found no major differences in echocardiographic and clinical follow-up between AS and AI, except for a significantly higher transvalvular gradient in the AS cohort (P = .01).

Conclusions: This study demonstrated good midterm outcomes of transcatheter aortic valve implantation with the J-Valve system in the treatment of patients with either AS or AI. It suggests that the J-Valve system is a promising alternative therapy in high-risk patients.

Citing Articles

Successful Percutaneous Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation in a High-risk Patient with Cardiorenal Syndrome.

Mutlu D, Inanc I, Zanbak Mutlu O, Marmagkiolis K, Iliescu C, Cilingiroglu M US Cardiol. 2024; 18:e20.

PMID: 39588174 PMC: 11588104. DOI: 10.15420/usc.2024.19.


Transapical Transcatheter Aortic Valve Replacement Under 3-Dimensional Guidance to Treat Pure Aortic Regurgitation in Patients with a Large Aortic Annulus.

Mao Y, Liu Y, Zhai M, Jin P, Wei L, Zhang H Rev Cardiovasc Med. 2024; 25(9):319.

PMID: 39355610 PMC: 11440419. DOI: 10.31083/j.rcm2509319.


A Coronary-Friendly Device Mitigating Risk of Coronary Obstruction in Transcatheter Aortic Valve Replacement.

Lu Y, Yin M, Yang Y, Wang W, Dong L, Yang X Clin Interv Aging. 2024; 19:1557-1570.

PMID: 39347480 PMC: 11439368. DOI: 10.2147/CIA.S467594.


Transcatheter aortic valve replacement for aortic regurgitation: a systematic review and meta-analysis.

Liu R, Fu Z, Jiang Z, Yan Y, Yao J, Liu X ESC Heart Fail. 2024; 11(6):3488-3500.

PMID: 38749505 PMC: 11631339. DOI: 10.1002/ehf2.14832.


Treatment options for isolated aortic valve insufficiency: a review.

Argaw S, Azizgolshani N, Blitzer D, Takayama H, George I, Pirelli L Front Cardiovasc Med. 2024; 11:1381102.

PMID: 38665234 PMC: 11043486. DOI: 10.3389/fcvm.2024.1381102.