» Articles » PMID: 32963025

International Recommendations for a Vascular Access Minimum Dataset: a Delphi Consensus-building Study

Abstract

Background: Data regarding vascular access device use and outcomes are limited. In part, this gap reflects the absence of guidance on what variables should be collected to assess patient outcomes. We sought to derive international consensus on a vascular access minimum dataset.

Methods: A modified Delphi study with three rounds (two electronic surveys and a face-to-face consensus panel) was conducted involving international vascular access specialists. In Rounds 1 and 2, electronic surveys were distributed to healthcare professionals specialising in vascular access. Survey respondents were asked to rate the importance of variables, feasibility of data collection and acceptability of items, definitions and response options. In Round 3, a purposive expert panel met to review Round 1 and 2 ratings and reach consensus (defined as ≥70% agreement) on the final items to be included in a minimum dataset for vascular access devices.

Results: A total of 64 of 225 interdisciplinary healthcare professionals from 11 countries responded to Round 1 and 2 surveys (response rate of 34% and 29%, respectively). From the original 52 items, 50 items across five domains emerged from the Delphi procedure.Items related to demographic and clinical characteristics (n=5; eg, age), device characteristics (n=5; eg, device type), insertion (n=16; eg, indication), management (n=9; eg, dressing and securement), and complication and removal (n=15, eg, occlusion) were identified as requirements for a minimum dataset to track and evaluate vascular access device use and outcomes.

Conclusion: We developed and internally validated a minimum dataset for vascular access device research. This study generated new knowledge to enable healthcare systems to collect relevant, useful and meaningful vascular access data. Use of this standardised approach can help benchmark clinical practice and target improvements worldwide.

Citing Articles

Determining the required data elements to develop the information management system for Iranian traditional medicine.

Mirzaeian R, Bahraini A, Kazemi-Arpanahi H BMC Complement Med Ther. 2025; 25(1):13.

PMID: 39825356 PMC: 11740590. DOI: 10.1186/s12906-025-04744-x.


Central venous access device adverse events in pediatric patients with cancer: a systematic review and meta-analysis.

Nunn J, Takashima M, Wray-Jones E, Raj T, Hanna D, Ullman A Support Care Cancer. 2024; 32(10):662.

PMID: 39283363 PMC: 11405478. DOI: 10.1007/s00520-024-08853-0.


Development and Preliminary Validation of a Central Venous Access Device-Associated Skin Impairment Classification Tool Using Modified Delphi and Clinimetric Methods.

Xu H, Campbell J, Takashima M, Larsen E, Coyer F, August D J Adv Nurs. 2024; 81(2):1095-1112.

PMID: 39258848 PMC: 11730755. DOI: 10.1111/jan.16416.


Determining the minimum data set of geriatric assessment at the Iran primary health care referral system: shifting from fragmentation to integration care for older people.

Mirzaeian R, Shafiee M, Afrash M, Kazemi-Arpanahi H BMC Health Serv Res. 2024; 24(1):1039.

PMID: 39244560 PMC: 11380327. DOI: 10.1186/s12913-024-11498-8.


Establishing a paediatric critical care core quality measure set using a multistakeholder, consensus-driven process.

Schults J, Charles K, Millar J, Rickard C, Chopra V, Lake A Crit Care Resusc. 2024; 26(2):71-79.

PMID: 39072236 PMC: 11282349. DOI: 10.1016/j.ccrj.2024.01.002.


References
1.
Harris P, Taylor R, Thielke R, Payne J, Gonzalez N, Conde J . Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2008; 42(2):377-81. PMC: 2700030. DOI: 10.1016/j.jbi.2008.08.010. View

2.
Chan R, Northfield S, Larsen E, Mihala G, Ullman A, Hancock P . Central venous Access device SeCurement And Dressing Effectiveness for peripherally inserted central catheters in adult acute hospital patients (CASCADE): a pilot randomised controlled trial. Trials. 2017; 18(1):458. PMC: 5628427. DOI: 10.1186/s13063-017-2207-x. View

3.
Alexandrou E, Ray-Barruel G, Carr P, Frost S, Inwood S, Higgins N . Use of Short Peripheral Intravenous Catheters: Characteristics, Management, and Outcomes Worldwide. J Hosp Med. 2018; 13(5). DOI: 10.12788/jhm.3039. View

4.
Takashima M, Ray-Barruel G, Ullman A, Keogh S, Rickard C . Randomized controlled trials in central vascular access devices: A scoping review. PLoS One. 2017; 12(3):e0174164. PMC: 5360326. DOI: 10.1371/journal.pone.0174164. View

5.
Reed T, Drozda Jr J, Baskin K, Tcheng J, Conway K, Wilson N . Advancing medical device innovation through collaboration and coordination of structured data capture pilots: Report from the Medical Device Epidemiology Network (MDEpiNet) Specific, Measurable, Achievable, Results-Oriented, Time Bound (SMART) Think.... Healthc (Amst). 2016; 5(4):158-164. DOI: 10.1016/j.hjdsi.2016.10.004. View