» Articles » PMID: 32953650

Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report

Overview
Specialty Orthopedics
Date 2020 Sep 21
PMID 32953650
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Complications of open reduction and internal fixation (ORIF) in four-part proximal humerus fractures (PHFs) include non-union, malunion, avascular necrosis of humeral head, and glenoid defect due to implant failure. Reverse total shoulder arthroplasty is a salvage procedure for cases of failed fixation. In cases with significant abnormal glenoid anatomy, custom-made patient-specific 3D printed jigs play a major role in pre-operative planning and accurate positioning of the glenoid component, thereby improving the final outcome. We report a case of salvage reverse shoulder arthroplasty done using the patient-specific custom-made 3D printed jig.

Case Report: A 58-year-old female sustained bilateral PHF due to electrocution and was treated with bilateral ORIF in single stage in February 2018.At 4 months from the time of surgery, the fracture on the left side had united, but there was non-union on the right side with screw penetration eroding the glenoid. Reverse shoulder arthroplasty was planned as a salvage procedure. Intraoperative, the glenoid was found to be small (2.7cm × 1.72cm) and there was a posterior glenoid defect due to screw penetration. During drilling for central peg, an iatrogenic glenoid fracture occurred. The procedure was deferred. After 4 months of conservative treatment, the glenoid fracture had united and then a definitive procedure with the reverse shoulder prosthesis was planned. 3D glenoid bone model was made based on the computed tomography scan and custom-made jigs are designed and 3D printed, which are specific for the patient. Reverse shoulder arthroplasty was done, and surgery went uneventful. The patient achieved active forward elevation of 110°, lateral elevation of 90°, and an external rotation of 10° at 1-year follow-up.

Conclusion: Reverse shoulder arthroplasty can be considered as a salvage procedure for failed fixation of PHF with predictable outcomes. Custom-made patient-specific 3D printed jigs in reverse shoulder arthroplasty are useful in assessing the position and direction of central peg in case of small glenoid and glenoid bone defects. 3D bone models are useful in implant selection also.

Citing Articles

Two-day staged bilateral reverse shoulder arthroplasty for traumatic proximal humerus fractures: a case report.

Romiyo V, Patel M, Rivera-Pintado C, Fedorka C JSES Rev Rep Tech. 2023; 3(1):111-115.

PMID: 37588077 PMC: 10426508. DOI: 10.1016/j.xrrt.2022.09.003.


Average Indian Glenoid Sizes Are Smaller than All Commercially Available Glenoid Components: A Systematic Review.

Paul S, Arora M, Das L, Raja B, Kalia R Indian J Orthop. 2023; 57(7):1008-1022.

PMID: 37384007 PMC: 10293529. DOI: 10.1007/s43465-023-00885-8.


One-step Bilateral Reverse Shoulder Replacement for Posterior Fracture-dislocation in a Young Alcoholic.

Vitali M, Bettinelli G, Montalbano F, Salini V J Orthop Case Rep. 2023; 12(5):11-14.

PMID: 36660149 PMC: 9826567. DOI: 10.13107/jocr.2022.v12.i05.2794.


Three Dimensional Anthropometric Analysis of Glenoid Anatomy in Normal Indian Population.

Bodanki C, Yadoji H, Maryada V, Venkata G Indian J Orthop. 2021; 55(4):861-868.

PMID: 34194640 PMC: 8192620. DOI: 10.1007/s43465-020-00321-1.

References
1.
Eltorai A, Nguyen E, Daniels A . Three-Dimensional Printing in Orthopedic Surgery. Orthopedics. 2015; 38(11):684-7. DOI: 10.3928/01477447-20151016-05. View

2.
Owsley K, Gorczyca J . Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg Am. 2008; 90(2):233-40. DOI: 10.2106/JBJS.F.01351. View

3.
Clavert P, Adam P, Bevort A, Bonnomet F, Kempf J . Pitfalls and complications with locking plate for proximal humerus fracture. J Shoulder Elbow Surg. 2009; 19(4):489-94. DOI: 10.1016/j.jse.2009.09.005. View

4.
Villatte G, Muller A, Pereira B, Mulliez A, Reilly P, Emery R . Use of Patient-Specific Instrumentation (PSI) for glenoid component positioning in shoulder arthroplasty. A systematic review and meta-analysis. PLoS One. 2018; 13(8):e0201759. PMC: 6104947. DOI: 10.1371/journal.pone.0201759. View

5.
Hussey M, Hussey S, Mighell M . Reverse shoulder arthroplasty as a salvage procedure after failed internal fixation of fractures of the proximal humerus: outcomes and complications. Bone Joint J. 2015; 97-B(7):967-72. DOI: 10.1302/0301-620X.97B7.35713. View