» Articles » PMID: 32936810

Replicable Simulation of Distal Hot Water Premise Plumbing Using Convectively-mixed Pipe Reactors

Overview
Journal PLoS One
Date 2020 Sep 16
PMID 32936810
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

A lack of replicable test systems that realistically simulate hot water premise plumbing conditions at the laboratory-scale is an obstacle to identifying key factors that support growth of opportunistic pathogens (OPs) and opportunities to stem disease transmission. Here we developed the convectively-mixed pipe reactor (CMPR) as a simple reproducible system, consisting of off-the-shelf plumbing materials, that self-mixes through natural convective currents and enables testing of multiple, replicated, and realistic premise plumbing conditions in parallel. A 10-week validation study was conducted, comparing three pipe materials (PVC, PVC-copper, and PVC-iron; n = 18 each) to stagnant control pipes without convective mixing (n = 3 each). Replicate CMPRs were found to yield consistent water chemistry as a function of pipe material, with differences becoming less discernable by week 9. Temperature, an overarching factor known to control OP growth, was consistently maintained across all 54 CMPRs, with a coefficient of variation <2%. Dissolved oxygen (DO) remained lower in PVC-iron (1.96 ± 0.29 mg/L) than in PVC (5.71 ± 0.22 mg/L) or PVC-copper (5.90 ± 0.38 mg/L) CMPRs as expected due to corrosion. Further, DO in PVC-iron CMPRs was 33% of that observed in corresponding stagnant pipes (6.03 ± 0.33 mg/L), demonstrating the important role of internal convective mixing in stimulating corrosion and microbiological respiration. 16S rRNA gene amplicon sequencing indicated that both bulk water (Padonis = 0.001, R2 = 0.222, Pbetadis = 0.785) and biofilm (Padonis = 0.001, R2 = 0.119, Pbetadis = 0.827) microbial communities differed between CMPR versus stagnant pipes, consistent with creation of a distinct ecological niche. Overall, CMPRs can provide a more realistic simulation of certain aspects of premise plumbing than reactors commonly applied in prior research, at a fraction of the cost, space, and water demand of large pilot-scale rigs.

Citing Articles

Influence of pipe materials on in-building disinfection of and in simulated hot water plumbing.

Cullom A, Spencer M, Williams M, Falkinham 3rd J, Pruden A, Edwards M Water Res X. 2023; 21:100189.

PMID: 38098877 PMC: 10719577. DOI: 10.1016/j.wroa.2023.100189.

References
1.
Silhan J, Corfitzen C, Albrechtsen H . Effect of temperature and pipe material on biofilm formation and survival of Escherichia coil in used drinking water pipes: a laboratory-based study. Water Sci Technol. 2006; 54(3):49-56. DOI: 10.2166/wst.2006.447. View

2.
Lytle D, Liggett J . Impact of water quality on chlorine demand of corroding copper. Water Res. 2016; 92:11-21. DOI: 10.1016/j.watres.2016.01.032. View

3.
Falkinham 3rd J, Hilborn E, Arduino M, Pruden A, Edwards M . Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. Environ Health Perspect. 2015; 123(8):749-58. PMC: 4529011. DOI: 10.1289/ehp.1408692. View

4.
Rhoads W, Pruden A, Edwards M . Convective Mixing in Distal Pipes Exacerbates Legionella pneumophila Growth in Hot Water Plumbing. Pathogens. 2016; 5(1). PMC: 4810150. DOI: 10.3390/pathogens5010029. View

5.
Quast C, Pruesse E, Yilmaz P, Gerken J, Schweer T, Yarza P . The SILVA ribosomal RNA gene database project: improved data processing and web-based tools. Nucleic Acids Res. 2012; 41(Database issue):D590-6. PMC: 3531112. DOI: 10.1093/nar/gks1219. View