» Articles » PMID: 32922994

Cole-impedance Parameters Representing Biceps Tissue Bioimpedance in Healthy Adults and Their Alterations Following Eccentric Exercise

Overview
Journal J Adv Res
Date 2020 Sep 14
PMID 32922994
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study is to identify if participation in an eccentric exercise protocol altered the Cole-impedance model parameters that represent localized bicep tissue bioimpedance. This supports continued efforts to identify which features of tissue bioimpedance may be effective markers to non-invasively identify skeletal muscle damage. Here, the Cole-impedance model parameters that best fit the localized electrical impedance of exercised (using an eccentric stimulus) and unexercised biceps of 6 participants (collected before, immediately after and at 24 h, 48 h, 72 h and 96 h) are determined using a numerical optimization technique. Statistical tests comparing the pre-exercise and post-exercise model parameters report significant decreases in and with significant increases in at 72 h and 96 h post-exercise for exercised biceps (aligning with noted periods of peak swelling). These changes in , and were not observed in the unexercised biceps. These results support that the parameter of the Cole-impedance model fit to bioimpedance data may be a suitable marker for identifying skeletal muscle damage.

Citing Articles

Bioimpedance measurements of fibrotic and acutely injured lung tissues.

Mir M, Chen J, Patel A, Pinezich M, Hudock M, Yoon A Acta Biomater. 2025; 194:270-287.

PMID: 39870150 PMC: 11877686. DOI: 10.1016/j.actbio.2025.01.039.


Methodology for integrated analysis of vector- and spectroscopic bioimpedance methods.

Bello J, Lafargue A, Ciria H, Luna T, Leyva Y J Electr Bioimpedance. 2024; 15(1):154-161.

PMID: 39717622 PMC: 11665879. DOI: 10.2478/joeb-2024-0018.


Association between muscle-localized bioelectrical impedance analysis parameters and performance in a multi-set exercise on the isokinetic dynamometer in young women.

Fukuoka A, Oliveira N, Matias C, Guariglia D, Guerra-Junior G, Goncalves E Eur J Sport Sci. 2024; 24(9):1319-1327.

PMID: 39106159 PMC: 11369348. DOI: 10.1002/ejsc.12167.


Development of a Tetherless Bioimpedance Device That Uses Morphologic Changes to Predict Blood Flow Restrictions Mimicking Peripheral Artery Disease Progression.

Hong S, Cote G Biosensors (Basel). 2024; 14(6).

PMID: 38920590 PMC: 11202059. DOI: 10.3390/bios14060286.


Enhancing In Vivo Electroporation Efficiency through Hyaluronidase: Insights into Plasmid Distribution and Optimization Strategies.

Maji D, Miguela V, Cameron A, Campbell D, Sasset L, Yao X Pharmaceutics. 2024; 16(4).

PMID: 38675208 PMC: 11053992. DOI: 10.3390/pharmaceutics16040547.


References
1.
Thompson B, Stock M, Banuelas V . Effects of Accumulating Work Shifts on Performance-Based Fatigue Using Multiple Strength Measurements in Day and Night Shift Nurses and Aides. Hum Factors. 2016; 59(3):346-356. DOI: 10.1177/0018720816677814. View

2.
Lauritzen F, Paulsen G, Raastad T, Bergersen L, Owe S . Gross ultrastructural changes and necrotic fiber segments in elbow flexor muscles after maximal voluntary eccentric action in humans. J Appl Physiol (1985). 2009; 107(6):1923-34. DOI: 10.1152/japplphysiol.00148.2009. View

3.
Heiss R, Hotfiel T, Kellermann M, May M, Wuest W, Janka R . Effect of Compression Garments on the Development of Edema and Soreness in Delayed-Onset Muscle Soreness (DOMS). J Sports Sci Med. 2018; 17(3):392-401. PMC: 6090402. View

4.
Li L, Shin H, Li X, Li S, Zhou P . Localized Electrical Impedance Myography of the Biceps Brachii Muscle during Different Levels of Isometric Contraction and Fatigue. Sensors (Basel). 2016; 16(4). PMC: 4851095. DOI: 10.3390/s16040581. View

5.
Rutkove S, Caress J, Cartwright M, Burns T, Warder J, David W . Electrical impedance myography as a biomarker to assess ALS progression. Amyotroph Lateral Scler. 2012; 13(5):439-45. PMC: 3422377. DOI: 10.3109/17482968.2012.688837. View