Unenhanced Magnetic Resonance Angiography As an Accurate Alternative in the Preoperative Assessment of Potential Living Kidney Donors with Contraindications to Computed Tomography Angiography and to Contrast-enhanced Magnetic Resonance Angiography

Abstract

Objective: To evaluate the accuracy of steady-state free precession (SSFP) unenhanced magnetic resonance angiography (MRA) at 1.5 T for the identification of multiple renal arteries, using computed tomography angiography (CTA) as the reference standard.

Materials And Methods: This was a prospective study involving 39 patients (26 males; mean age, 62.6 years) who underwent CTA and unenhanced MRA to evaluate the proximal and middle segments of the renal arteries. The analysis was performed in two phases: the quality of unenhanced MRA images was classified as diagnostic or nondiagnostic for the presence of multiple renal arteries by two independent readers; two other independent readers then evaluated the images previously classified as being of diagnostic quality. The sensitivity, specificity, and overall accuracy of unenhanced MRA were calculated, CTA being used as the reference standard. The kappa statistic was used in order to calculate interobserver agreement.

Results: The image quality of unenhanced MRA was considered diagnostic in 70-90% of the extrarenal arterial segments. The CTA examination revealed 19 multiple renal arteries (8 on the right and 11 on the left). The accuracy of unenhanced MRA for the identification of multiple renal arteries was greater than 90%, with a sensitivity of 72.7-100% and a specificity of 96.3-100%.

Conclusion: Unenhanced MRA provides high quality imaging of the extrarenal segments of renal arteries. This method may be used as an alternative for the evaluation of the renal arteries, given that it has an accuracy comparable to that of CTA.

References
1.
Fraioli F, Catalano C, Bertoletti L, Danti M, Fanelli F, Napoli A . Multidetector-row CT angiography of renal artery stenosis in 50 consecutive patients: prospective interobserver comparison with DSA. Radiol Med. 2006; 111(3):459-68. DOI: 10.1007/s11547-006-0042-3. View

2.
Zhang N, Zou L, Huang Y, Liu D, Tang Y, Fan Z . Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes. PLoS One. 2015; 10(6):e0128786. PMC: 4452776. DOI: 10.1371/journal.pone.0128786. View

3.
Lanzman R, Kropil P, Schmitt P, Freitag S, Ringelstein A, Wittsack H . Nonenhanced free-breathing ECG-gated steady-state free precession 3D MR angiography of the renal arteries: comparison between 1.5 T and 3 T. AJR Am J Roentgenol. 2010; 194(3):794-8. DOI: 10.2214/AJR.09.2814. View

4.
Xu J, Shi D, Li Y, Zhang J, Zhu S, Shen H . Non-enhanced MR angiography of renal artery using inflow-sensitive inversion recovery pulse sequence: a prospective comparison with enhanced CT angiography. Eur J Radiol. 2010; 80(2):e57-63. DOI: 10.1016/j.ejrad.2010.08.004. View

5.
Maki J, Wilson G, Eubank W, Glickerman D, Millan J, Hoogeveen R . Navigator-gated MR angiography of the renal arteries: a potential screening tool for renal artery stenosis. AJR Am J Roentgenol. 2007; 188(6):W540-6. DOI: 10.2214/AJR.06.1138. View