» Articles » PMID: 32898204

Diagnostic Accuracy of Ultrasound Superb Microvascular Imaging for Breast Tumor: a Meta-analysis

Overview
Journal Med Ultrason
Specialty Radiology
Date 2020 Sep 8
PMID 32898204
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: This meta-analysis aimed to identify the accuracy of ultrasound superb microvascular imaging (SMI) for the diagnosis of a breast tumor.

Material And Method: We searched PubMed, Web of Science, Google Scholar, Cochrane Library, EBSCO, and CBM databases from January 1st, 2013 until February 1st, 2020 without language restrictions. Meta-analysis was conducted using STATA version 14.0 and Meta-Disc version 1.4 software. We calculated the summary statistics for sensitivity (Sen), specificity (Spe), positive and negative likelihood ratio (LR+/LR-), diagnostic odds ratio (DOR) and receiver operating characteristic (SROC) curve.

Results: Fifteen studies that met all inclusion criteria were included in this meta-analysis. A total of 955 breast neoplasm patients and 1116 patients with benign breast tumors were assessed. All breast lesions were histologically confirmed after SMI. The pooled Sen was 0.81 (95%CI=0.78-0.83); the pooled Spe was 0.71 (95%CI=0.68-0.73) The pooled LR+ was 3.24 (95%CI=2.27-4.64); the pooled negative LR-was 0.25 (95%CI=0.18-0.34) The pooled DOR of SMI in the diagnosis of breast tumor was 46.97 (95 % CI=16.72∼131.97). The area under the SROC curve was 0.87 (95%CI=0.84- 0.90). We found no evidence for publication bias (t=-0.84, p=0.42).

Conclusion: Our meta-analysis indicates that SMI may have a high diagnostic accuracy in differential diagnosis between benign and malignant breast tumors. Thus, SMI may be a good tool for the diagnosis of breast tumors.

Citing Articles

Using a combination of superb microvascular imaging and other auxiliary ultrasound techniques to increase the accuracy of gray-scale ultrasound for breast masses.

Abedi M, Sahebi L, Eslami B, Saberi A, Orouji M, Alipour S BMC Cancer. 2024; 24(1):224.

PMID: 38365653 PMC: 10873956. DOI: 10.1186/s12885-024-11981-9.


A ultrasonic nomogram of quantitative parameters for diagnosing breast cancer.

Wang C, Che Y Sci Rep. 2023; 13(1):12340.

PMID: 37524926 PMC: 10390567. DOI: 10.1038/s41598-023-39686-2.


Diagnostic Value of Superb Microvascular Imaging in Differentiating Benign and Malignant Breast Tumors: A Systematic Review and Meta-Analysis.

Feng J, Lu J, Jin C, Chen Y, Chen S, Guo G Diagnostics (Basel). 2022; 12(11).

PMID: 36359491 PMC: 9689350. DOI: 10.3390/diagnostics12112648.


3D Harmonic and Subharmonic Imaging for Characterizing Breast Lesions: A Multi-Center Clinical Trial.

Forsberg F, Piccoli C, Sridharan A, Wilkes A, Sevrukov A, Ojeda-Fournier H J Ultrasound Med. 2021; 41(7):1667-1675.

PMID: 34694019 PMC: 9884499. DOI: 10.1002/jum.15848.


Superb Microvascular Imaging Technology Can Improve the Diagnostic Efficiency of the BI-RADS System.

Cai S, Wang H, Zhang X, Zhang L, Zhu Q, Sun Q Front Oncol. 2021; 11:634752.

PMID: 34249681 PMC: 8263934. DOI: 10.3389/fonc.2021.634752.