» Articles » PMID: 32858838

Minimising Blood Stream Infection: Developing New Materials for Intravascular Catheters

Overview
Specialty Pharmacology
Date 2020 Aug 30
PMID 32858838
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Catheter related blood stream infection is an ever present hazard for those patients requiring venous access and particularly for those requiring long term medication. The implementation of more rigorous care bundles and greater adherence to aseptic techniques have yielded substantial reductions in infection rates but the latter is still far from acceptable and continues to place a heavy burden on patients and healthcare providers. While advances in engineering design and the arrival of functional materials hold considerable promise for the development of a new generation of catheters, many challenges remain. The aim of this review is to identify the issues that presently impact catheter performance and provide a critical evaluation of the design considerations that are emerging in the pursuit of these new catheter systems.

Citing Articles

Medical Device-Associated Biofilm Infections and Multidrug-Resistant Pathogens.

Bouhrour N, Nibbering P, Bendali F Pathogens. 2024; 13(5).

PMID: 38787246 PMC: 11124157. DOI: 10.3390/pathogens13050393.


Integration of Riboflavin-Modified Carbon Fiber Mesh Electrode Systems in a 3D-Printed Catheter Hub.

Casimero C, Smith R, Davis J Micromachines (Basel). 2024; 15(1).

PMID: 38258198 PMC: 10818592. DOI: 10.3390/mi15010079.


Phyto-assisted synthesis of zinc oxide nanoparticles for developing antibiofilm surface coatings on central venous catheters.

Malhotra A, Chauhan S, Rahaman M, Tripathi R, Khanuja M, Chauhan A Front Chem. 2023; 11:1138333.

PMID: 37035110 PMC: 10076889. DOI: 10.3389/fchem.2023.1138333.


[Update of the recommendations of the Bacteraemia Zero Project].

Gallart E, Delicado M, Nuvials X Enferm Intensiva. 2022; 33:S31-S39.

PMID: 35911623 PMC: 9315357. DOI: 10.1016/j.enfi.2022.06.002.


Even the Simplest Devices May Malfunction: Split Septum Design Revisited.

Naftalovich R, Char S, Iskander A, Naftalovich D Biomed Instrum Technol. 2021; 55(1):41-43.

PMID: 33690818 PMC: 8641422. DOI: 10.2345/0899-8205-55.1.41.

References
1.
Tarakji K, Ellis C, Defaye P, Kennergren C . Cardiac Implantable Electronic Device Infection in Patients at Risk. Arrhythm Electrophysiol Rev. 2016; 5(1):65-71. PMC: 4939310. DOI: 10.15420/aer.2015.27.2. View

2.
Jacobs B, Schilling S, Doellman D, Hutchinson N, Rickey M, Nelson S . Central venous catheter occlusion: a prospective, controlled trial examining the impact of a positive-pressure valve device. JPEN J Parenter Enteral Nutr. 2004; 28(2):113-8. DOI: 10.1177/0148607104028002113. View

3.
Sato A, Nakamura I, Fujita H, Tsukimori A, Kobayashi T, Fukushima S . Peripheral venous catheter-related bloodstream infection is associated with severe complications and potential death: a retrospective observational study. BMC Infect Dis. 2017; 17(1):434. PMC: 5474015. DOI: 10.1186/s12879-017-2536-0. View

4.
Bouza E, Burillo A, Munoz P . Catheter-related infections: diagnosis and intravascular treatment. Clin Microbiol Infect. 2002; 8(5):265-74. DOI: 10.1046/j.1469-0691.2002.00385.x. View

5.
Jarvis W, Murphy C, Hall K, Fogle P, Karchmer T, Harrington G . Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors. Clin Infect Dis. 2009; 49(12):1821-7. DOI: 10.1086/648418. View