Implant Primary Stability with an Osteocondensation Drilling Protocol in Different Density Polyurethane Blocks

Overview
Publisher Informa Healthcare
Date 2020 Aug 26
PMID 32840129
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

The implant primary stability is a fundamental condition for avoiding implant micro-motions that might result in fibrous encapsulation; its achievement is facilitated by macro- and micro-geometry of the implant, and by the bone density and architecture at the intended implant site. The aim was to evaluate an osteocondensing drilling protocol for dental implant positioning compared to standard protocol on polyurethane block. A total of 40 implants, 20 for each osteocondensing group (Test) and 20 for standard drilling group (Control), were positioned. Insertion torque (IT), removal torque (RT), and Periotest were measured. A IT, RT, and Periotest significant difference was present in favor of the implant osteocondensing protocol. The results suggested that osteocondensing protocol represents a useful technique for implant placement in poor density bone.

Citing Articles

Evaluation of Effect of Different Insertion Speeds and Torques on Implant Placement Condition and Removal Torque in Polyurethane Dense D1 Bone Model.

Orhan Z, Cigerim L Polymers (Basel). 2024; 16(10).

PMID: 38794554 PMC: 11125928. DOI: 10.3390/polym16101361.


Advancing Postoperative Pain Management in Oral Cancer Patients: A Systematic Review.

Inchingolo A, Dipalma G, Inchingolo A, Palumbo I, Guglielmo M, Morolla R Pharmaceuticals (Basel). 2024; 17(4).

PMID: 38675500 PMC: 11054702. DOI: 10.3390/ph17040542.


"Compression Necrosis" - A Cause of Concern for Early Implant Failure? Case Report and Review of Literature.

Ramesh R, Sasi A, Mohamed S, Joseph S Clin Cosmet Investig Dent. 2024; 16:43-52.

PMID: 38469322 PMC: 10926919. DOI: 10.2147/CCIDE.S453798.


Autologous Tooth Granulometry and Specific Surface Area with Three Grinding Methods: An In Vitro Study.

Ribes B, Fernandez-Baca I, Mur J, Lopez-Malla Matute J, Aragoneses Lamas J Materials (Basel). 2024; 17(4).

PMID: 38399026 PMC: 10890256. DOI: 10.3390/ma17040773.


The influence of truncated-conical implant length on primary stability in maxillary and mandibular regions: an in vitro study using polyurethane blocks.

Romasco T, Pignatelli P, Tumedei M, Hossein H, Cipollina A, Piattelli A Clin Oral Investig. 2023; 28(1):28.

PMID: 38147179 DOI: 10.1007/s00784-023-05444-x.