» Articles » PMID: 32831479

Wearable Electrochemical Glove-based Sensor for Rapid and On-site Detection of Fentanyl

Overview
Date 2020 Aug 25
PMID 32831479
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

Rapid, on-site detection of fentanyl is of critical importance, as it is an extremely potent synthetic opioid that is prone to abuse. Here we describe a wearable glove-based sensor that can detect fentanyl electrochemically on the fingertips towards decentralized testing for opioids. The glove-based sensor consists of flexible screen-printed carbon electrodes modified with a mixture of multiwalled carbon nanotubes and a room temperature ionic liquid, 4-(3-butyl-1-imidazolio)-1-butanesulfonate). The sensor shows direct oxidation of fentanyl in both liquid and powder forms with a detection limit of 10 μM using square-wave voltammetry. The "Lab-on-a-Glove" sensors, combined with a portable electrochemical analyzer, provide wireless transmission of the measured data to a smartphone or tablet for further analysis. The integrated sampling and sensing methodology on the thumb and index fingers, respectively, enables rapid screening of fentanyl in the presence of a mixture of cutting agents and offers considerable promise for timely point-of-need screening for first responders. Such a glove-based "swipe, scan, sense, and alert" strategy brings chemical analytics directly to the user's fingertips and opens new possibilities for detecting substances of abuse in emergency situations.

Citing Articles

Novel interfaces for internet of wearable electrochemical sensors.

Shahzad S, Iftikhar F, Shah A, Rehman H, Iwuoha E RSC Adv. 2024; 14(49):36713-36732.

PMID: 39559568 PMC: 11570917. DOI: 10.1039/d4ra07165d.


The Evolution of Illicit-Drug Detection: From Conventional Approaches to Cutting-Edge Immunosensors-A Comprehensive Review.

Anzar N, Suleman S, Singh Y, Kumari S, Parvez S, Pilloton R Biosensors (Basel). 2024; 14(10).

PMID: 39451690 PMC: 11506482. DOI: 10.3390/bios14100477.


Submersible voltammetric sensing probe for rapid and extended remote monitoring of opioids in community water systems.

Zhou J, Ding S, S Sandhu S, Chang A, Taechamahaphan A, Gudekar S Mikrochim Acta. 2024; 191(8):463.

PMID: 38995455 PMC: 11245449. DOI: 10.1007/s00604-024-06520-z.


Revolutionary Point-of-Care Wearable Diagnostics for Early Disease Detection and Biomarker Discovery through Intelligent Technologies.

Haghayegh F, Norouziazad A, Haghani E, Feygin A, Rahimi R, Ghavamabadi H Adv Sci (Weinh). 2024; 11(36):e2400595.

PMID: 38958517 PMC: 11423253. DOI: 10.1002/advs.202400595.


Capture and Detection of Aerosolized Fentanyl in a Suspended Electrochemical Cell.

Vannoy K, Krushinski L, Dick J Anal Chem. 2024; 96(26):10648-10653.

PMID: 38896456 PMC: 11223095. DOI: 10.1021/acs.analchem.4c01321.


References
1.
Ling W, Mooney L, Hillhouse M . Prescription opioid abuse, pain and addiction: clinical issues and implications. Drug Alcohol Rev. 2011; 30(3):300-5. PMC: 4170948. DOI: 10.1111/j.1465-3362.2010.00271.x. View

2.
Mishra R, Martin A, Nakagawa T, Barfidokht A, Lu X, Sempionatto J . Detection of vapor-phase organophosphate threats using wearable conformable integrated epidermal and textile wireless biosensor systems. Biosens Bioelectron. 2017; 101:227-234. DOI: 10.1016/j.bios.2017.10.044. View

3.
Goodchild S, Hubble L, Mishra R, Li Z, Yugender Goud K, Barfidokht A . Ionic Liquid-Modified Disposable Electrochemical Sensor Strip for Analysis of Fentanyl. Anal Chem. 2019; 91(5):3747-3753. DOI: 10.1021/acs.analchem.9b00176. View

4.
Anastasova S, Crewther B, Bembnowicz P, Curto V, Ip H, Rosa B . A wearable multisensing patch for continuous sweat monitoring. Biosens Bioelectron. 2016; 93:139-145. DOI: 10.1016/j.bios.2016.09.038. View

5.
Scholl L, Seth P, Kariisa M, Wilson N, Baldwin G . Drug and Opioid-Involved Overdose Deaths - United States, 2013-2017. MMWR Morb Mortal Wkly Rep. 2019; 67(5152):1419-1427. PMC: 6334822. DOI: 10.15585/mmwr.mm675152e1. View