Stenting As Porous Media in Anatomically Accurate Geometries. A Comparison of Models and Spatial Heterogeneity

Overview
Journal J Biomech
Specialty Physiology
Date 2020 Aug 23
PMID 32827768
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Modelling intracranial aneurysm blood flow after flow diverter treatment has proven to be of great scientific and clinical interest. One of the reasons for not having CFD as an everyday clinical tool yet is the time required to set-up such simulations plus the required computational time. The speed-up of these simulations can have a considerable impact during treatment planning and device selection. Modelling flow diverters as a porous medium (PM) can considerably improve the computational time. Many models have been presented in literature, but quantitative comparisons between models are scarce. In this study, the untreated case, the explicit definition of the flow diverter wires as no-slip boundary condition and five different porous medium models were chosen for comparison, and evaluated on intracranial aneurysm of 14 patients with different shapes, sizes, and locations. CFD simulations were made using finite volume method on steady flow conditions. Velocities, kinetic energy, wall shear stress, and computational time were assessed for each model. Then, all models are compared against the no-slip boundary condition using non parametric Kolmogorov-Smirnov test. The model with least performance showed a mean K-S statistic of 0.31 and deviance of 0.2, while the model with best values always gave K-S statistics below 0.2. Kinetic energy between PM models varied between an over estimation of 218.3% and an under estimation of 73.06%. Also, speedups were between 4.75x and 5.3x (stdev: 0.38x and 0.15x) when using PM models. Flow diverters can be simulated with PM with a good agreement to standard CFD simulations were FD wires are represented with no-slip boundary condition in less than a quarter of the time. Best results were obtained on PM models based on geometrical properties, in particular, when using a heterogeneous medium based on equations for flat rhomboidal wire frames.

Citing Articles

Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection.

Dazeo N, Orlando J, Garcia C, Munoz R, Obrado L, Fernandez H Cardiovasc Eng Technol. 2024; 15(6):691-703.

PMID: 39160330 DOI: 10.1007/s13239-024-00745-y.


Prediction of Cerebral Aneurysm Hemodynamics With Porous-Medium Models of Flow-Diverting Stents via Deep Learning.

Li G, Song X, Wang H, Liu S, Ji J, Guo Y Front Physiol. 2021; 12:733444.

PMID: 34603085 PMC: 8484706. DOI: 10.3389/fphys.2021.733444.