» Articles » PMID: 32823930

Development of Hourly Indoor PM Concentration Prediction Model: The Role of Outdoor Air, Ventilation, Building Characteristic, and Human Activity

Overview
Publisher MDPI
Date 2020 Aug 23
PMID 32823930
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Exposure to indoor particulate matter less than 2.5 µm in diameter (PM) is a critical health risk factor. Therefore, measuring indoor PM concentrations is important for assessing their health risks and further investigating the sources and influential factors. However, installing monitoring instruments to collect indoor PM data is difficult and expensive. Therefore, several indoor PM concentration prediction models have been developed. However, these prediction models only assess the daily average PM concentrations in cold or temperate regions. The factors that influence PM concentration differ according to climatic conditions. In this study, we developed a prediction model for hourly indoor PM concentrations in Taiwan (tropical and subtropical region) by using a multiple linear regression model and investigated the impact factor. The sample comprised 93 study cases (1979 measurements) and 25 potential predictor variables. Cross-validation was performed to assess performance. The prediction model explained 74% of the variation, and outdoor PM concentrations, the difference between indoor and outdoor CO levels, building type, building floor level, bed sheet cleaning, bed sheet replacement, and mosquito coil burning were included in the prediction model. Cross-validation explained 75% of variation on average. The results also confirm that the prediction model can be used to estimate indoor PM concentrations across seasons and areas. In summary, we developed a prediction model of hourly indoor PM concentrations and suggested that outdoor PM concentrations, ventilation, building characteristics, and human activities should be considered. Moreover, it is important to consider outdoor air quality while occupants open or close windows or doors for regulating ventilation rate and human activities changing also can reduce indoor PM concentrations.

Citing Articles

Long-Term Exposure to Fine Particulate Matter and the Deterioration of Estimated Glomerular Filtration Rate: A Cohort Study in Patients With Pre-End-Stage Renal Disease.

Wu Y, Wu C, Chung M, Chen C, Wu L, Chung C Front Public Health. 2022; 10:858655.

PMID: 35462847 PMC: 9024125. DOI: 10.3389/fpubh.2022.858655.

References
1.
Clark N, Allen R, Hystad P, Wallace L, Dell S, Foty R . Exploring variation and predictors of residential fine particulate matter infiltration. Int J Environ Res Public Health. 2010; 7(8):3211-24. PMC: 2954577. DOI: 10.3390/ijerph7083211. View

2.
Gurung G, Bradley J, Delgado-Saborit J . Effects of shisha smoking on carbon monoxide and PM2.5 concentrations in the indoor and outdoor microenvironment of shisha premises. Sci Total Environ. 2016; 548-549:340-346. DOI: 10.1016/j.scitotenv.2015.12.093. View

3.
Lim J, Jeong J, Lee J, Moon J, Chung Y, Kim K . The analysis of PM2.5 and associated elements and their indoor/outdoor pollution status in an urban area. Indoor Air. 2010; 21(2):145-55. DOI: 10.1111/j.1600-0668.2010.00691.x. View

4.
Yuchi W, Gombojav E, Boldbaatar B, Galsuren J, Enkhmaa S, Beejin B . Evaluation of random forest regression and multiple linear regression for predicting indoor fine particulate matter concentrations in a highly polluted city. Environ Pollut. 2018; 245:746-753. DOI: 10.1016/j.envpol.2018.11.034. View

5.
Majd E, McCormack M, Davis M, Curriero F, Berman J, Connolly F . Indoor air quality in inner-city schools and its associations with building characteristics and environmental factors. Environ Res. 2018; 170:83-91. PMC: 6360122. DOI: 10.1016/j.envres.2018.12.012. View