Background And Purpose: Endovascular navigation through tortuous vessels can be complex. Tools that can optimise this access phase need to be developed. Our aim was to evaluate the feasibility of supra-aortic vessel catheterization guidance by means of live fluoroscopy fusion with MR angiography or CT angiography.

Materials And Methods: Twenty-five patients underwent preinterventional diagnostic MRA, and 8 patients underwent CTA. Fusion guidance was evaluated in 35 sessions of catheterization, targeting a total of 151 supra-aortic vessels. The time for MRA/CTA segmentation and fluoroscopy with MRA/CTA coregistration was recorded. The feasibility of fusion guidance was evaluated by recording the catheterizations executed by interventional neuroradiologists according to a standard technique under fluoroscopy and conventional road-mapping independent of the fusion guidance. Precision of the fusion roadmap was evaluated by measuring (on a semiquantitative 3-point scale) the maximum offset between the position of the guidewires/catheters and the vasculature on the virtual CTA/MRA images. The targeted vessels were divided in 2 groups according to their position from the level of the aortic arch.

Results: The average time needed for segmentation and image coregistration was 7 ± 2 minutes. The MRA/CTA virtual roadmap overlaid on live fluoroscopy was considered accurate in 84.8% (128/151) of the assessed landmarks, with a higher accuracy for the group of vessels closer to the aortic arch (92.4%; OR, 4.88; 95% CI, 1.83-11.66; = .003).

Conclusions: Fluoroscopy with MRA/CTA fusion guidance for supra-aortic vessel interventions is feasible. Further improvements of the technique to increase accuracy at the cervical level and further studies are needed for assessing the procedural time savings and decreasing the x-ray radiation exposure.

Citing Articles

Catheter navigation support for mechanical thrombectomy guidance: 3D/2D multimodal catheter-based registration with no contrast dye fluoroscopy.

de Turenne A, Eugene F, Blanc R, Szewczyk J, Haigron P Int J Comput Assist Radiol Surg. 2023; 19(3):459-468.

PMID: 37964153 DOI: 10.1007/s11548-023-03034-6.

References
1.
Kobeiter H, Nahum J, Becquemin J . Zero-contrast thoracic endovascular aortic repair using image fusion. Circulation. 2011; 124(11):e280-2. DOI: 10.1161/CIRCULATIONAHA.110.014118. View

2.
Kaladji A, Giovannetti M, Pascot R, Clochard E, Daoudal A, Lucas A . Preoperative CT-scan-based sizing and in-stent restenosis in peripheral endovascular revascularizations. Vascular. 2017; 25(5):504-513. DOI: 10.1177/1708538117700764. View

3.
Schulz C, Schmitt M, Bockler D, Geisbusch P . Feasibility and accuracy of fusion imaging during thoracic endovascular aortic repair. J Vasc Surg. 2015; 63(2):314-22. DOI: 10.1016/j.jvs.2015.08.089. View

4.
Madhwal S, Rajagopal V, Bhatt D, Bajzer C, Whitlow P, Kapadia S . Predictors of difficult carotid stenting as determined by aortic arch angiography. J Invasive Cardiol. 2008; 20(5):200-4. View

5.
Goudeketting S, Heinen S, van den Heuvel D, van Strijen M, de Haan M, Slump C . The use of 3D image fusion for percutaneous transluminal angioplasty and stenting of iliac artery obstructions: validation of the technique and systematic review of literature. J Cardiovasc Surg (Torino). 2017; 59(1):26-36. DOI: 10.23736/S0021-9509.17.10224-7. View