» Articles » PMID: 32819528

Quality of Life and Health Care Utilization in the CIRCA-DOSE Study

Abstract

Objectives: This study evaluated the impact of contact force-guided radiofrequency ablation versus cryoballoon ablation on quality of life and health care utilization.

Background: Traditional outcome parameters, such as arrhythmia-free survival, are insufficient to evaluate the clinical impact of atrial fibrillation (AF), as it fails to the capture patient- and health system-level differences in treatment approaches.

Methods: The CIRCA-DOSE (Cryoballoon Vs. Contact-Force Atrial Fibrillation Ablation) study randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency or cryoballoon ablation. Health-related quality-of-life (HRQOL) was assessed at baseline, and at 6 and 12 months post-ablation using a disease-specific and generic HRQOL instruments. Health care utilization (hospitalization, emergency department visits, and cardioversion) and antiarrhythmic drug use for the 12 months preceding ablation was compared with the 12 months following ablation.

Results: Disease-specific and generic HRQOL was moderately to severely impaired at baseline and improved significantly at 6 and 12 months of follow-up (median improvement in AFEQT [Atrial Fibrillation Effect on QualiTy of Life] score 32.4 [interquartile range: 17.7 to 48.9]). When compared with the 12 months pre-ablation, the proportion and absolute number of cardioversions decreased significantly (41.1% vs. 10.1% of patients, 137 vs. 35 events; p < 0.0001). Similar significant reductions in emergency department visits (66.7% vs. 25.1% of patients, 224 vs. 87 events; p < 0.0001), and hospitalizations (25.5% vs. 14.5% of patients, 86 vs. 50 events; p < 0.001) were observed. There were no significant differences between randomized groups.

Conclusions: In this multicenter randomized trial, catheter ablation with advanced-generation technologies resulted in a significant improvement in HRQOL and a significant reduction in health care utilization in the year following AF ablation. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE]; NCT01913522).

Citing Articles

Long-term outcomes of cryoballoon versus robotic magnetic navigation guided radiofrequency ablation in patients with persistent atrial fibrillation.

Luo Q, Li X, Xie Y, Bao Y, Wei Y, Lin C Sci Rep. 2025; 15(1):6181.

PMID: 39979454 PMC: 11842544. DOI: 10.1038/s41598-025-90920-5.


Long-Term Patient-Reported Outcomes After Radiofrequency Ablation and Cryoballoon Ablation for Paroxysmal Atrial Fibrillation: The Effect of Additional Ablations.

Antoun I, Kotb A, Vali Z, Abdelrazik A, Koev I, Safwan K J Cardiovasc Dev Dis. 2024; 11(12).

PMID: 39728275 PMC: 11676108. DOI: 10.3390/jcdd11120385.


Quality of Life in Patients with Atrial Fibrillation Undergoing Pulmonary Vein Isolation: Short-Term Follow-Up Study.

Linde M, Jubele K, Kupics K, Nikitina A, Erglis A Medicina (Kaunas). 2024; 60(10).

PMID: 39459381 PMC: 11509510. DOI: 10.3390/medicina60101594.


Factors Associated with Quality of Life among People with Atrial Fibrillation: Jordan Atrial Fibrillation Registry Study.

Al-Bashaireh A, Alkouri O, Alharbi A, Khader Y, Hammoudeh A, Aljawarneh Y Medicina (Kaunas). 2024; 60(8).

PMID: 39202543 PMC: 11356530. DOI: 10.3390/medicina60081262.


Ablation to Reduce Atrial Fibrillation Burden and Improve Outcomes: JACC Review Topic of the Week.

Schwennesen H, Andrade J, Wood K, Piccini J J Am Coll Cardiol. 2023; 82(10):1039-1050.

PMID: 37648353 PMC: 11103629. DOI: 10.1016/j.jacc.2023.06.029.