Pulse Rate Variability: a New Biomarker, Not a Surrogate for Heart Rate Variability

Overview
Publisher Biomed Central
Specialty Social Sciences
Date 2020 Aug 20
PMID 32811571
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

With the popularization of pulse wave signals by the spread of wearable watch devices incorporating photoplethysmography (PPG) sensors, many studies are reporting the accuracy of pulse rate variability (PRV) as a surrogate of heart rate variability (HRV). However, the authors are concerned about their research paradigm based on the assumption that PRV is a biomarker that reflects the same biological properties as HRV. Because PPG pulse wave and ECG R wave both reflect the periodic beating of the heart, pulse rate and heart rate should be equal, but it does not guarantee that the respective variabilities are also the same. The process from ECG R wave to PPG pulse wave involves several transformation steps of physical properties, such as those of electromechanical coupling and conversions from force to volume, volume to pressure, pressure impulse to wave, pressure wave to volume, and volume to light intensity. In fact, there is concreate evidence that shows discrepancy between PRV and HRV, such as that demonstrating the presence of PRV in the absence of HRV, differences in PRV with measurement sites, and differing effects of body posture and exercise between them. Our observations in adult patients with an implanted cardiac pacemaker also indicate that fluctuations in R-R intervals, pulse transit time, and pulse intervals are modulated differently by autonomic functions, respiration, and other factors. The authors suggest that it is more appropriate to recognize PRV as a different biomarker than HRV. Although HRV is a major determinant of PRV, PRV is caused by many other sources of variability, which could contain useful biomedical information that is neither error nor noise.

Citing Articles

Performance of a medical smartband with photoplethysmography technology and artificial intelligence algorithm to detect atrial fibrillation.

Blok S, Gielen W, Piek M, Hoeksema W, Tulevski I, Somsen G Mhealth. 2025; 11:5.

PMID: 39944860 PMC: 11811644. DOI: 10.21037/mhealth-24-10.


Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction.

Lu Z, Yang J, Tao K, Li X, Xu H, Qiu J Sensors (Basel). 2024; 24(16).

PMID: 39205108 PMC: 11360153. DOI: 10.3390/s24165412.


Continuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study.

Gaur P, Temple D, Hegarty-Craver M, Boyce M, Holt J, Wenger M JMIR Form Res. 2024; 8:e53977.

PMID: 39110968 PMC: 11339560. DOI: 10.2196/53977.


Non-invasive pulse arrival time is associated with cardiac index in pediatric heart transplant patients with normal ejection fraction.

Kwon S, Weinerman B, Nametz D, Megjhani M, Lee I, Habib A Physiol Meas. 2024; 45(7).

PMID: 38986482 PMC: 11262133. DOI: 10.1088/1361-6579/ad61b9.


Alleviating premenstrual symptoms with smartphone-based heart rate variability biofeedback training: a pilot study.

Blaser B, Weymar M, Wendt J Front Digit Health. 2024; 6:1337667.

PMID: 38946728 PMC: 11211633. DOI: 10.3389/fdgth.2024.1337667.


References
1.
Gil E, Orini M, Bailon R, Vergara J, Mainardi L, Laguna P . Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions. Physiol Meas. 2010; 31(9):1271-90. DOI: 10.1088/0967-3334/31/9/015. View

2.
Lu G, Yang F, Taylor J, Stein J . A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects. J Med Eng Technol. 2009; 33(8):634-41. DOI: 10.3109/03091900903150998. View

3.
Rapalis A, Petrenas A, Simaityte M, Bailon R, Marozas V . Towards pulse rate parametrization during free-living activities using smart wristband. Physiol Meas. 2018; 39(5):055007. DOI: 10.1088/1361-6579/aac24a. View

4.
Weinschenk S, Beise R, Lorenz J . Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects. Eur J Appl Physiol. 2016; 116(8):1527-35. DOI: 10.1007/s00421-016-3401-3. View

5.
Yuda E, Yamamoto K, Yoshida Y, Hayano J . Differences in pulse rate variability with measurement site. J Physiol Anthropol. 2020; 39(1):4. PMC: 7035641. DOI: 10.1186/s40101-020-0214-1. View