» Articles » PMID: 32811293

Comparison of Femur Strain Under Different Loading Scenarios: Experimental Testing

Overview
Date 2020 Aug 20
PMID 32811293
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Bone fracture, formation and adaptation are related to mechanical strains in bone. Assessing bone stiffness and strain distribution under different loading conditions may help predict diseases and improve surgical results by determining the best conditions for long-term functioning of bone-implant systems. In this study, an experimentally wide range of loading conditions (56) was used to cover the directional range spanned by the hip joint force. Loads for different stance configurations were applied to composite femurs and assessed in a material testing machine. The experimental analysis provides a better understanding of the influence of the bone inclination angle in the frontal and sagittal planes on strain distribution and stiffness. The results show that the surface strain magnitude and stiffness vary significantly under different loading conditions. For the axial compression, maximal bending is observed at the mid-shaft, and bone stiffness is also maximal. The increased inclination leads to decreased stiffness and increased magnitude of maximum strain at the distal end of the femur. For comparative analysis of results, a three-dimensional, finite element model of the femur was used. To validate the finite element model, strain gauges and digital image correlation system were employed. During validation of the model, regression analysis indicated robust agreement between the measured and predicted strains, with high correlation coefficient and low root-mean-square error of the estimate. The results of stiffnesses obtained from multi-loading conditions experiments were qualitatively compared with results obtained from a finite element analysis of the validated model of femur with the same multi-loading conditions. When the obtained numerical results are qualitatively compared with experimental ones, similarities can be noted. The developed finite element model of femur may be used as a promising tool to estimate proximal femur strength and identify the best conditions for long-term functioning of the bone-implant system in future study.

Citing Articles

Strains on the human femur after revision total knee arthroplasty: An in vitro study using digital image correlation.

Sporer E, Schilling C, Tait R, Giurea A, Grupp T PLoS One. 2024; 19(6):e0305387.

PMID: 38870168 PMC: 11175519. DOI: 10.1371/journal.pone.0305387.


Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants.

Baleani M, Erani P, Acciaioli A, Schileo E Bioengineering (Basel). 2024; 11(4).

PMID: 38671816 PMC: 11048186. DOI: 10.3390/bioengineering11040395.


The Impact of Coronal Configuration of the Proximal Femur on its Mechanical Properties and the Validation of a New Theoretical Model: Finite Element Analysis and Biomechanical Examination.

Zhang L, Zhu B, Chen L, Wang W, Zhang X, Zhang J Orthop Surg. 2022; 15(1):62-69.

PMID: 36250538 PMC: 9837247. DOI: 10.1111/os.13537.


An Experimental and Virtual Approach to Hip Revision Prostheses.

Duta A, Popa D, Vintila D, Buciu G, Dina N, Ionescu A Diagnostics (Basel). 2022; 12(8).

PMID: 36010302 PMC: 9406961. DOI: 10.3390/diagnostics12081952.