Wear of an Ion-releasing Powder/liquid Polymer Resin in Relation to That of Glass-ionomer and Conventional Resin Composites

Overview
Journal Am J Dent
Specialty Dentistry
Date 2020 Aug 15
PMID 32794389
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate the wear in vitro of a new ion-releasing powder/liquid polymer resin in relation to that of glass-ionomer derivatives and conventional composites.

Methods: Flat specimens (eight per material) of the ion-releasing powder/liquid polymer resin Cention N, five resin-modified glass-ionomer cements [ChemFil Rock, Equia Fil (with and without coating), Fuji II, Photac Fil, Riva], six conventional glass-ionomer cements (Fuji IX, Fuji IX GP, Ionofil Molar, Ketac Fil Plus, Ketac Molar, Ketac Universal), and two popular conventional resin composites (CeramX, Filtek Z350 XT) were processed and luted to aluminum holders. After storage in water at 37°C for 24 hours, the specimens were polished to 2,500 grit and subjected to the Ivoclar wear method, which mainly simulates attrition wear using a commercially available chewing simulator. A standardized stylus made of pressable ceramic (IPS Empress) hits flat specimens 120,000 times with a 5 kg weight and a lateral movement of 0.7 mm under constant exchange of water at different temperatures (5°C/55°C). The vertical loss was measured on plaster replicas with a laser scanner and 3D software. The Ivoclar wear method moderately correlates with clinical wear.

Results: The mean vertical wear of the resin-modified glass-ionomer cements was statistically significantly higher, between 616±44 µm (Ionofil Molar) and 946±101 µm (Fuji IX GP) than that of the ion-releasing polymer resin Cention N (327±63 µm) (ANOVA post-hoc Tukey B, P< 0.01), which was in the same statistical group of the conventional resin CeramX (323±31 µm). Filtek Z350 XT showed significantly lower wear (221±19 µm) (ANOVA post-hoc Tukey B, P< 0.05). The materials ChemFil Rock (39±13 µm), Photac Fil (41±9 µm), and Fuji II (42±8 µm) had the lowest antagonist wear, while Ketac Fil Universal (143±37 µm) and CeramX (135±13 µm) had the highest antagonist wear. Antagonist wear for Cention N was somewhere in between (90±21 µm).

Clinical Significance: For the restoration of posterior Class II and large Class I restorations, resin-based materials should be chosen over resin-modified or conventional glass-ionomer cements.

Citing Articles

Alkasite restorative material for endodontically treated teeth: a randomized controlled pilot study.

Bepu D, Scatolin R, Franco N, Sanchez L, Souza-Gabriel A, Corona S Restor Dent Endod. 2024; 49(3):e24.

PMID: 39247650 PMC: 11377874. DOI: 10.5395/rde.2024.49.e24.


Evaluation of a Method to Determine Wear Resistance of Class I Tooth Restorations during Cyclic Loading.

Messer-Hannemann P, Samadi M, Bottcher H, Duy S, Duy D, Albrecht N Materials (Basel). 2022; 15(15).

PMID: 35955375 PMC: 9369466. DOI: 10.3390/ma15155440.


An alkasite restorative material effectively remineralized artificial interproximal enamel caries in vitro.

Theerarath T, Sriarj W Clin Oral Investig. 2022; 26(6):4437-4445.

PMID: 35190884 DOI: 10.1007/s00784-022-04407-y.