» Articles » PMID: 32746362

Time Stamp - A Novel Time-to-Digital Demodulation Method for Bioimpedance Implant Applications

Overview
Publisher IEEE
Date 2020 Aug 4
PMID 32746362
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Bioimpedance analysis is a noninvasive and inexpensive technology used to investigate the electrical properties of biological tissues. The analysis requires demodulation to extract the real and imaginary parts of the impedance. Conventional systems use complex architectures such as I-Q demodulation. In this paper, a very simple alternative time-to-digital demodulation method or 'time stamp' is proposed. It employs only three comparators to identify or stamp in the time domain, the crossing points of the excitation signal, and the measured signal. In a CMOS proof of concept design, the accuracy of impedance magnitude and phase is 97.06% and 98.81% respectively over a bandwidth of 10 kHz to 500 kHz. The effect of fractional-N synthesis is analysed for the counter-based zero crossing phase detector obtaining a finer phase resolution (0.51˚ at 500 kHz) using a counter clock frequency ( f = 12.5 MHz). Because of its circuit simplicity and ease of transmitting the time stamps, the method is very suited to implantable devices requiring low area and power consumption.

Citing Articles

Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm.

Ausin J, Ramos J, Lorido A, Molina P, Duque-Carrillo J Sensors (Basel). 2023; 23(16).

PMID: 37631594 PMC: 10457917. DOI: 10.3390/s23167055.


A novel method for in-situ extracting bio-impedance model parameters optimized for embedded hardware.

Simic M, Freeborn T, Sekara T, Stavrakis A, Jeoti V, Stojanovic G Sci Rep. 2023; 13(1):5070.

PMID: 36977800 PMC: 10050187. DOI: 10.1038/s41598-023-31860-w.


FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation.

Tsukahara A, Yamaguchi T, Tanaka Y, Ueno A Sensors (Basel). 2022; 22(12).

PMID: 35746187 PMC: 9228433. DOI: 10.3390/s22124406.


An Impedance Readout IC with Ratio-Based Measurement Techniques for Electrical Impedance Spectroscopy.

Cheon S, Kweon S, Kim Y, Koo J, Ha S, Je M Sensors (Basel). 2022; 22(4).

PMID: 35214475 PMC: 8876594. DOI: 10.3390/s22041563.


Localized Bioimpedance Measurements with the MAX3000x Integrated Circuit: Characterization and Demonstration.

Critcher S, Freeborn T Sensors (Basel). 2021; 21(9).

PMID: 33923037 PMC: 8123364. DOI: 10.3390/s21093013.