Elongation Index As a Sensitive Measure of Cell Deformation in High-Throughput Microfluidic Systems

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 2020 Jul 23
PMID 32697978
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

One of the promising approaches for high-throughput screening of cell mechanotype is microfluidic deformability cytometry (mDC), in which the apparent deformation index (DI) of the cells stretched by extensional flow at the stagnation point of a cross-slot microchannel is measured. The DI is subject to substantial measurement errors due to cell offset from the flow centerline and velocity fluctuations in inlet channels, leading to artificial widening of DI versus cell size plots. Here, we simulated an mDC experiment using a custom computational algorithm for viscoelastic cell migration. Cell motion and deformation in a cross-slot channel was modeled for fixed or randomized values of cellular mechanical properties (diameter, shear elasticity, cortical tension) and initial cell placement, with or without sinusoidal fluctuations between the inlet velocities. Our numerical simulation indicates that mDC loses sensitivity to changes in shear elasticity when the offset distance exceeds 5 μm, and just 1% velocity fluctuation causes an 11.7% drop in the DI. The obtained relationships between the cell diameter, shear elasticity, and offset distance were used to establish a new measure of cell deformation, referred to as the "elongation index" (EI). In the randomized study, the EI scatter plots were visibly separated for the low- and high-elasticity populations of cells, with a mean of 300 and 3500 Pa, whereas the standard DI output was unable to distinguish between these two groups of cells. The successful suppression of the offset artifacts with a narrower data distribution was shown for the EI output of MCF-7 cells.

Citing Articles

Conditions for a microfluidic creep experiment for microparticles using a cross-slot extensional flow device.

Ghanbarpour Mamaghani S, Dahl J Biomicrofluidics. 2025; 19(2):024102.

PMID: 40060272 PMC: 11888784. DOI: 10.1063/5.0239475.


Microfluidic technologies for cell deformability cytometry.

Chen H, Guo J, Bian F, Zhao Y Smart Med. 2024; 1(1):e20220001.

PMID: 39188737 PMC: 11235995. DOI: 10.1002/SMMD.20220001.


Numerical investigation of the dynamics of a rigid spherical particle in a vortical cross-slot flow at moderate inertia.

Kechagidis K, Owen B, Guillou L, Tse H, Di Carlo D, Kruger T Microsyst Nanoeng. 2023; 9:100.

PMID: 37519826 PMC: 10372015. DOI: 10.1038/s41378-023-00541-z.


Blood Rheological Characterization of β-Thalassemia Trait and Iron Deficiency Anemia Using Front Microrheometry.

Mendez-Mora L, Cabello-Fusares M, Ferre-Torres J, Riera-Llobet C, Krishnevskaya E, Trejo-Soto C Front Physiol. 2021; 12:761411.

PMID: 34744796 PMC: 8566979. DOI: 10.3389/fphys.2021.761411.


Non-invasive acquisition of mechanical properties of cells via passive microfluidic mechanisms: A review.

Li Z, Yang X, Zhang Q, Yang W, Zhang H, Liu L Biomicrofluidics. 2021; 15(3):031501.

PMID: 34178202 PMC: 8205512. DOI: 10.1063/5.0052185.

References
1.
Bento D, Rodrigues R, Faustino V, Pinho D, Fernandes C, Pereira A . Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements. Micromachines (Basel). 2018; 9(4). PMC: 6187860. DOI: 10.3390/mi9040151. View

2.
Liu H, Tan Q, Geddie W, Jewett M, Phillips N, Ke D . Biophysical characterization of bladder cancer cells with different metastatic potential. Cell Biochem Biophys. 2013; 68(2):241-6. DOI: 10.1007/s12013-013-9702-9. View

3.
Tanyeri M, Johnson-Chavarria E, Schroeder C . Hydrodynamic trap for single particles and cells. Appl Phys Lett. 2010; 96(22):224101. PMC: 2892531. DOI: 10.1063/1.3431664. View

4.
Lekka M, Gil D, Pogoda K, Dulinska-Litewka J, Jach R, Gostek J . Cancer cell detection in tissue sections using AFM. Arch Biochem Biophys. 2012; 518(2):151-6. DOI: 10.1016/j.abb.2011.12.013. View

5.
Shashni B, Ariyasu S, Takeda R, Suzuki T, Shiina S, Akimoto K . Size-Based Differentiation of Cancer and Normal Cells by a Particle Size Analyzer Assisted by a Cell-Recognition PC Software. Biol Pharm Bull. 2018; 41(4):487-503. DOI: 10.1248/bpb.b17-00776. View