» Articles » PMID: 32566827

Fluorous-Phase Ion-Selective PH Electrodes: Electrode Body and Ionophore Optimization for Measurements in the Physiological PH Range

Overview
Journal ACS Omega
Specialty Chemistry
Date 2020 Jun 23
PMID 32566827
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Because of their low polarity and polarizability, fluorous sensing membranes are both hydrophobic and lipophobic and exhibit very high ion selectivities. Here, we report on a new fluorous-membrane ion-selective electrode (ISE) with a wide sensing range centered around physiologically relevant pH values. The fluorophilic tris[perfluoro(octyl)butyl]amine (N[(CH)R]) was synthesized and tested as a new H ionophore using a redesigned electrode body that provides excellent mechanical sealing and much improved measurement reliability. In a challenging 1 M KCl background, these fluorous-phase ISEs exhibit a sensing range from pH 2.2 to 11.2, which is one of the widest working ranges reported to date for ionophore-based H ISEs. High selectivities against common interfering ions such as K, Na, and Ca were determined (selectivity coefficients: log = - 11.6; log = - 12.4; log < - 10.2). The use of the N[(CH)R] ionophore with its -(CH)- spacers separating the amino group from the strongly electron-withdrawing perfluorooctyl groups improved the potentiometric selectivity as compared to the less basic tris[perfluoro(octyl)propyl]amine ionophore. The use of N[(CH)R] also made the ISE less prone to counter anion failure (i.e., Donnan failure) at low pH than the use of tris[perfluoro(octyl)pentyl]amine with its longer -(CH)- spacers, which more effectively shield the amino center from the perfluorooctyl groups. In addition, we exposed both conventional plasticized PVC-phase pH ISEs and fluorous-phase pH ISEs to 10% serum for 5 days. Results show that the PVC-phase ISEs lost selectivity while their fluorous-phase counterparts did not.

Citing Articles

Flexible Acetylcholine Neural Probe with a Hydrophobic Laser-Induced Graphene Electrode and a Fluorous-Phase Sensing Membrane.

Amirghasemi F, Al-Shami A, Ushijima K, Mousavi M ACS Mater Lett. 2024; 6(9):4158-4167.

PMID: 39309214 PMC: 11415234. DOI: 10.1021/acsmaterialslett.4c00825.


Rapid and Convenient Potentiometric Method for Determining Fluorosulfate, a Byproduct of the Fumigant and Greenhouse Gas Sulfuryl Fluoride.

Chen Z, Wang C, Pignatello J ACS Omega. 2024; 9(21):23013-23020.

PMID: 38826532 PMC: 11137687. DOI: 10.1021/acsomega.4c02629.


FAST (Flexible Acetylcholine Sensing Thread): Real-Time Detection of Acetylcholine with a Flexible Solid-Contact Potentiometric Sensor.

Amirghasemi F, Soleimani A, Bawarith S, Tabassum A, Morrel A, Mousavi M Bioengineering (Basel). 2023; 10(6).

PMID: 37370586 PMC: 10294826. DOI: 10.3390/bioengineering10060655.


A simple optical pH sensor based on pectin and L-derived anthocyanin for fish freshness monitoring.

Nazaruddin N, Afifah N, Bahi M, Susilawati S, Sani N, Esmaeili C F1000Res. 2021; 10:422.

PMID: 34527216 PMC: 8366298. DOI: 10.12688/f1000research.52836.2.

References
1.
Gunsolus I, Mousavi M, Hussein K, Buhlmann P, Haynes C . Effects of Humic and Fulvic Acids on Silver Nanoparticle Stability, Dissolution, and Toxicity. Environ Sci Technol. 2015; 49(13):8078-86. PMC: 4643692. DOI: 10.1021/acs.est.5b01496. View

2.
Shultz M, Stefanova O, Mokrov S, Mikhelson K . Potentiometric estimation of the stability constants of ion-lonophore complexes in ion-selective membranes by the sandwich membrane method: theory, advantages, and limitations. Anal Chem. 2002; 74(3):510-7. DOI: 10.1021/ac015564f. View

3.
Boswell P, Szijjarto C, Jurisch M, Gladysz J, Rabai J, Buhlmann P . Fluorophilic ionophores for potentiometric pH determinations with fluorous membranes of exceptional selectivity. Anal Chem. 2008; 80(6):2084-90. DOI: 10.1021/ac702161c. View

4.
Buhlmann P, Pretsch E, Bakker E . Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. Chem Rev. 2002; 98(4):1593-1688. DOI: 10.1021/cr970113+. View

5.
Ceresa A, Radu A, Peper S, Bakker E, Pretsch E . Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit. Anal Chem. 2002; 74(16):4027-36. DOI: 10.1021/ac025548y. View