» Articles » PMID: 32560269

A Dynamic Hanging-Drop System for Mesenchymal Stem Cell Culture

Overview
Journal Int J Mol Sci
Publisher MDPI
Date 2020 Jun 21
PMID 32560269
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

There have been many microfluid technologies combined with hanging-drop for cell culture gotten developed in the past decade. A common problem within these devices is that the cell suspension introduced at the central inlet could cause a number of cells in each microwell to not regularize. Also, the instability of droplets during the spheroid formation remains an unsolved ordeal. In this study, we designed a microfluidic-based hanging-drop culture system with the design of taper-tube that can increase the stability of droplets while enhancing the rate of liquid exchange. A ring is surrounding the taper-tube. The ring can hold the cells to enable us to seed an adequate amount of cells before perfusion. Moreover, during the period of cell culture, the mechanical force around the cell is relatively low to prevent stem cells from differentiate and maintain the phenotype. As a result of our hanging system design, cells are designed to accumulate at the bottom of the droplet. This method enhances convenience for observation activities and analysis of experiments. Thus, this microfluid chip can be used as an in vitro platform representing in vivo physiological conditions, and can be useful in regenerative therapy.

Citing Articles

3D Culture of MSCs for Clinical Application.

Gao Q, Cekuc M, Ergul Y, Pius A, Shinohara I, Murayama M Bioengineering (Basel). 2025; 11(12.

PMID: 39768017 PMC: 11726872. DOI: 10.3390/bioengineering11121199.


Three-dimensional models: from cell culture to Patient-Derived Organoid and its application to future liposarcoma research.

Tahara S, Rentsch S, DE Faria F, Sarchet P, Karna R, Calore F Oncol Res. 2024; 33(1):1-13.

PMID: 39735679 PMC: 11671414. DOI: 10.32604/or.2024.053635.


Spheroid-Exosome-Based Bioprinting Technology in Regenerative Medicine.

Lee H, Lee J J Funct Biomater. 2024; 15(11).

PMID: 39590549 PMC: 11595066. DOI: 10.3390/jfb15110345.


Uniform sized cancer spheroids production using hydrogel-based droplet microfluidics: a review.

Kim S, Lam P, Jayaraman A, Han A Biomed Microdevices. 2024; 26(2):26.

PMID: 38806765 PMC: 11241584. DOI: 10.1007/s10544-024-00712-3.


Advances in the application of extracellular vesicles derived from three-dimensional culture of stem cells.

Chen W, Wu P, Jin C, Chen Y, Li C, Qian H J Nanobiotechnology. 2024; 22(1):215.

PMID: 38693585 PMC: 11064407. DOI: 10.1186/s12951-024-02455-y.


References
1.
Andolfi L, Greco S, Tierno D, Chignola R, Martinelli M, Giolo E . Planar AFM macro-probes to study the biomechanical properties of large cells and 3D cell spheroids. Acta Biomater. 2019; 94:505-513. DOI: 10.1016/j.actbio.2019.05.072. View

2.
Andrikovics H, orfi Z, Meggyesi N, Bors A, Varga L, Kovy P . Current Trends in Applications of Circulatory Microchimerism Detection in Transplantation. Int J Mol Sci. 2019; 20(18). PMC: 6769866. DOI: 10.3390/ijms20184450. View

3.
Nekanti U, Rao V, Bahirvani A, Jan M, Totey S, Ta M . Long-term expansion and pluripotent marker array analysis of Wharton's jelly-derived mesenchymal stem cells. Stem Cells Dev. 2009; 19(1):117-30. DOI: 10.1089/scd.2009.0177. View

4.
Todorov L, VadeBoncouer T . Etiology and use of the "hanging drop" technique: a review. Pain Res Treat. 2014; 2014:146750. PMC: 4009264. DOI: 10.1155/2014/146750. View

5.
Fallahi H, Zhang J, Phan H, Nguyen N . Flexible Microfluidics: Fundamentals, Recent Developments, and Applications. Micromachines (Basel). 2019; 10(12). PMC: 6953028. DOI: 10.3390/mi10120830. View