» Articles » PMID: 32550120

Successful Strategy for the Conservative Management of Acquired Tracheoesophageal Fistula Due to Lithium Button Battery Ingestion

Overview
Publisher Thieme
Specialty Pediatrics
Date 2020 Jun 19
PMID 32550120
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

A 16-month-old boy was referred to our hospital for the management of suspected lithium button battery (LBB) ingestion. He had been previously well, but became febrile with a persistent cough resistant to oral antibiotics and dysphagia for 5 days. Radiography identified an LBB lodged in the upper esophagus. The LBB was retrieved under direct visualization with rigid laryngoscopy. He was sedated for 5 days and enteral feeding was commenced through a nasojejunal tube on the next day after procedure. On day 8 after retrieval, endoscopy and fluoroscopy identified a tracheoesophageal fistula (TEF), 6 mm in diameter. Conservative management was conducted with periodic follow-up endoscopies, which showed signs of healing in the esophagus. Following continuous antibiotics and proactive nutritional support, the TEF was found to have closed spontaneously by day 28 after the LBB removal. We present our experience of the successful nonsurgical management of acquired TEF secondary to LBB ingestion and aim to establish a protocol for managing it conservatively by reviewing the relevant literature.

Citing Articles

A Peculiar Tracheoesophageal Fistula Caused by a Plastic Foreign Body.

Chen C, Dai D, Guo Y, Sun C, Li Q Case Rep Otolaryngol. 2025; 2025:3983529.

PMID: 39959123 PMC: 11824707. DOI: 10.1155/crot/3983529.


Video Laryngoscope Assistance in Button Battery Retrieval.

Ren S, Lopes H, Masters N Case Rep Anesthesiol. 2023; 2023:8550685.

PMID: 37711750 PMC: 10499533. DOI: 10.1155/2023/8550685.


A2 Years Old Boy with Recurrent Tracheoesophageal Fistula After Surgical Removal of an Esophageal Button Battery.

Alhawsawi S, Alshamrani A, Muhammad T Am J Case Rep. 2022; 23:e937810.

PMID: 36310365 PMC: 9634829. DOI: 10.12659/AJCR.937810.

References
1.
Eliason M, Ricca R, Gallagher T . Button battery ingestion in children. Curr Opin Otolaryngol Head Neck Surg. 2017; 25(6):520-526. DOI: 10.1097/MOO.0000000000000410. View

2.
Russell R, Cohen M, Billmire D . Tracheoesophageal fistula following button battery ingestion: successful non-operative management. J Pediatr Surg. 2013; 48(2):441-4. DOI: 10.1016/j.jpedsurg.2012.11.040. View

3.
VOTTELER T, NASH J, Rutledge J . The hazard of ingested alkaline disk batteries in children. JAMA. 1983; 249(18):2504-6. View

4.
Imamoglu M, Cay A, Kosucu P, Ahmetoglu A, Sarihan H . Acquired tracheo-esophageal fistulas caused by button battery lodged in the esophagus. Pediatr Surg Int. 2004; 20(4):292-4. DOI: 10.1007/s00383-003-1129-8. View

5.
Senthilkumaran G, Crankson S, Yousef M . Spontaneous closure of acquired tracheo-oesophageal fistula. J Laryngol Otol. 1996; 110(7):685-7. DOI: 10.1017/s0022215100134632. View