» Articles » PMID: 32546225

Minimum Accelerometer Wear-time for Reliable Estimates of Physical Activity and Sedentary Behaviour of People Receiving Haemodialysis

Overview
Journal BMC Nephrol
Publisher Biomed Central
Specialty Nephrology
Date 2020 Jun 18
PMID 32546225
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Low levels of physical activity are implicated in low life expectancies of people receiving maintenance haemodialysis. Accelerometers are increasingly being used to quantify activity behaviours of this population but guidance to quality-assure such data is lacking. The objective of this study was to provide data processing and reduction recommendations to ensure accelerometer-derived outcomes are sufficiently reliable for interpretative analysis.

Methods: Seventy people receiving maintenance haemodialysis (age 55.9 ± 15.7 years, 34% women, 23% diabetic) from a single outpatient renal unit volunteered for the study. Participants wore Actigraph GT3x and ActivPAL monitors during waking hours over seven days. Reliability of accelerometer output (normalised to wear-time) was assessed via intraclass correlation coefficient (ICC). The Spearman-Brown prophecy formula was subsequently applied to the ICCs to derive the minimum required accelerometer wear-time for each behavioural outcome.

Results: Monitor wear compliance was greater on dialysis compared to non-dialysis days (90% v 77%). Participants were significantly more active on non-dialysis days compared to dialysis days but there were no significant differences in estimated behaviours between days within the same condition. Average measure ICCs for all accelerometer outcomes were high (range 0.76-0.96). Computations indicated that habitual physical activity and sedentary behaviour could be estimated with a minimum reliability level of 0.80 from one dialysis day and two non-dialysis days, and at least eight hours monitor wear per day. Applying this rubric allowed 90% of participant data to be retained for further analysis.

Conclusions: Regardless of accelerometer, one dialysis and two non-dialysis days data with a minimum of eight hours wear each day should enable habitual activity of people receiving maintenance haemodialysis to be characterised with acceptable reliability. These recommendations reconcile the tension between wear-time criteria stringency and retention of an adequately representative sample.

Citing Articles

Using wearable technology to objectively investigate physical behaviour and determine health outcomes of a physical activity intervention in patients with psoriasis.

Sheppard R, Gan W, Onambele-Pearson G, Young H Skin Health Dis. 2024; 4(6):e473.

PMID: 39624729 PMC: 11608874. DOI: 10.1002/ski2.473.


To Identify and Compare ActivPAL Objectively Measured Activity Levels With Self-Reported Activity From the International Physical Activity Questionnaire in Older Adults With Intellectual Disability.

Lynch L, McCarron M, McCallion P, Burke E J Appl Res Intellect Disabil. 2024; 38(1):e13327.

PMID: 39622078 PMC: 11611362. DOI: 10.1111/jar.13327.


Characterizing daily physical activity patterns with unsupervised learning via functional mixture models.

Ensari I, Caceres B, Jackman K, Goldsmith J, Suero-Tejeda N, Odlum M J Behav Med. 2024; 48(1):149-161.

PMID: 39306631 DOI: 10.1007/s10865-024-00519-w.


Impact of physical activity on surrogate markers of cardiovascular disease in the haemodialysis population.

Hull K, Abell L, Adenwalla S, Billany R, Burns S, Burton J Clin Kidney J. 2024; 17(7):sfae198.

PMID: 39050864 PMC: 11267219. DOI: 10.1093/ckj/sfae198.


Diagnostic accuracy of step count as an indicator of sedentary behavior in patients with end-stage kidney disease on hemodialysis.

Jesus L, Pinheiro B, Alvarenga B, Paticcie G, Oliveira C, Lucinda L J Nephrol. 2024; 37(3):777-779.

PMID: 38300434 DOI: 10.1007/s40620-023-01881-9.


References
1.
da Costa Rosa C, Nishimoto D, Junior I, Ciolac E, Monteiro H . Factors Associated With Levels of Physical Activity in Chronic Kidney Disease Patients Undergoing Hemodialysis: The Role of Dialysis Versus Nondialysis Day. J Phys Act Health. 2017; 14(9):726-732. DOI: 10.1123/jpah.2016-0715. View

2.
Baria F, Kamimura M, Avesani C, Lindholm B, Stenvinkel P, Draibe S . Activity-related energy expenditure of patients undergoing hemodialysis. J Ren Nutr. 2010; 21(3):226-34. DOI: 10.1053/j.jrn.2010.06.022. View

3.
Gretebeck R, Montoye H . Variability of some objective measures of physical activity. Med Sci Sports Exerc. 1992; 24(10):1167-72. View

4.
Evenson K, Catellier D, Gill K, Ondrak K, McMurray R . Calibration of two objective measures of physical activity for children. J Sports Sci. 2008; 26(14):1557-65. DOI: 10.1080/02640410802334196. View

5.
Masse L, Fuemmeler B, Anderson C, Matthews C, Trost S, Catellier D . Accelerometer data reduction: a comparison of four reduction algorithms on select outcome variables. Med Sci Sports Exerc. 2005; 37(11 Suppl):S544-54. DOI: 10.1249/01.mss.0000185674.09066.8a. View