Abstract

Although 1st and 2nd generation supraglottic airway devices (SADs) have many desirable features, they are nevertheless inserted in a similar 'blind' way as their 1st generation predecessors. Clinicians mostly still rely entirely on subjective indirect assessments to estimate correct placement which supposedly ensures a tight seal. Malpositioning and potential airway compromise occurs in more than half of placements. Vision-guided insertion can improve placement. In this article we propose the development of a 3rd generation supraglottic airway device, equipped with cameras and fiberoptic illumination, to visualise insertion of the device, enable immediate manoeuvres to optimise SAD position, verify whether correct 1st and 2nd seals are achieved and check whether size selected is appropriate. We do not provide technical details of such a '3rd generation' device, but rather present a theoretical analysis of its desirable properties, which are essential to overcome the remaining limitations of current 1st and 2nd generation devices. We also recommend that this further milestone improvement, i.e. ability to place the SAD accurately under direct vision, be eligible for the moniker '3rd generation'. Blind insertion of SADs should become the exception and we anticipate, as in other domains such as central venous cannulation and nerve block insertions, vision-guided placement becoming the gold standard.

Citing Articles

How does head position affect laryngeal vision with a video laryngeal mask airway?.

Castillo-Monzon C, Marroquin-Valz H, Gaszynski T, Cayuela M, Orozco J, Ratajczyk P Front Med (Lausanne). 2025; 11:1469225.

PMID: 39741507 PMC: 11686431. DOI: 10.3389/fmed.2024.1469225.


Effect of the new video laryngeal mask airway SaCoVLM on airway management in lateral laparoscopic urological surgery: A single center randomized controlled trial.

Sun Y, Zhang M, Gao X, Gao Z, Zou T, Guo Y Sci Rep. 2024; 14(1):2132.

PMID: 38272937 PMC: 10810894. DOI: 10.1038/s41598-024-51856-4.


New Devices, Innovative Technologies, and Non-Standard Techniques for Airway Management: A Narrative Review.

Gaszynski T, Gomez-Rios M, Serrano-Moraza A, Sastre J, Lopez T, Ratajczyk P Healthcare (Basel). 2023; 11(18).

PMID: 37761667 PMC: 10650429. DOI: 10.3390/healthcare11182468.


Supraglottic Airway Devices with Vision Guided Systems: Third Generation of Supraglottic Airway Devices.

Castillo-Monzon C, Gaszynski T, Marroquin-Valz H, Orozco-Montes J, Ratajczyk P J Clin Med. 2023; 12(16).

PMID: 37629238 PMC: 10455808. DOI: 10.3390/jcm12165197.


Comparison of Clinical Performance of C-MAC Video Laryngoscope Guided vs Blind Placement of I-Gel® in Paediatric Patients: A Randomized Controlled Open-Label Trial.

Kumar R, Bihani P, Mohammed S, Syal R, Bhatia P, Jaju R Turk J Anaesthesiol Reanim. 2023; 51(4):347-353.

PMID: 37587678 PMC: 10440480. DOI: 10.4274/TJAR.2023.221010.


References
1.
Tanoubi I, Sun J, Drolet P, Fortier L, Donati F . Replacing a double-lumen tube with a single-lumen tube or a laryngeal mask airway device to reduce coughing at emergence after thoracic surgery: a randomized controlled single-blind trial. Can J Anaesth. 2015; 62(9):988-95. DOI: 10.1007/s12630-015-0403-2. View

2.
Kwanten L, Madhivathanan P . Supraglottic airway devices: current and future uses. Br J Hosp Med (Lond). 2018; 79(1):31-35. DOI: 10.12968/hmed.2018.79.1.31. View

3.
Stix M, OConnor Jr C . Maximum minute ventilation test for the ProSeal laryngeal mask airway. Anesth Analg. 2002; 95(6):1782-7, table of contents. DOI: 10.1097/00000539-200212000-00059. View

4.
Liu E, Goy R, Chen F . The LMA CTrach, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth. 2006; 96(3):396-400. DOI: 10.1093/bja/ael001. View

5.
Christodoulou C . ProSeal laryngeal mask airway foldover detection. Anesth Analg. 2004; 99(1):312-313. DOI: 10.1213/01.ANE.0000127714.32845.7F. View