Accurate Real-time FNO Expirograms Using Complementary Optical Sensors

Overview
Journal J Breath Res
Specialty Pulmonary Medicine
Date 2020 Jun 13
PMID 32531773
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The fraction of exhaled nitric oxide (FNO) is an important biomarker for the diagnosis and management of asthma and other pulmonary diseases associated with airway inflammation. In this study we report on a novel method for accurate, highly time-resolved, real time detection of FNO at the mouth. The experimental arrangement is based on a combination of optical sensors for the determination of the temporal profile of exhaled NO and CO concentrations. Breath CO and exhalation flow are measured at the mouth using diode laser absorption spectroscopy (at 2 μm) and differential pressure sensing, respectively. NO is determined in a sidestream configuration using a quantum cascade laser based, cavity-enhanced absorption cell (at 5.2 μm) which simultaneously measures sidestream CO. The at-mouth and sidestream CO measurements are used to enable the deconvolution of the sidestream NO measurement back to the at-mouth location. All measurements have a time resolution of 0.1 s, limited by the requirement of a reasonable limit of detection for the NO measurement, which on this timescale is 4.7 ppb (2 σ). Using this methodology, NO expirograms (FNOgrams) were measured and compared for eight healthy volunteers. The FNOgrams appear to differ qualitatively between individuals and the hope is that the dynamic information encoded in these FNOgrams will provide valuable additional insight into the location of the inflammation in the airways and potentially predict a response to therapy. A validation of the measurements at low-time resolution is provided by checking that results from previous studies that used a two-compartment model of NO production can be reproduced using our technology.

Citing Articles

Exhaled Biomarkers for Point-of-Care Diagnosis: Recent Advances and New Challenges in Breathomics.

Kiss H, Orlos Z, Gellert A, Megyesfalvi Z, Mikaczo A, Sarkozi A Micromachines (Basel). 2023; 14(2).

PMID: 36838091 PMC: 9964519. DOI: 10.3390/mi14020391.


Ultrasensitive multispecies spectroscopic breath analysis for real-time health monitoring and diagnostics.

Liang Q, Chan Y, Changala P, Nesbitt D, Ye J, Toscano J Proc Natl Acad Sci U S A. 2021; 118(40).

PMID: 34599098 PMC: 8501790. DOI: 10.1073/pnas.2105063118.


Determination of nitric oxide using light-emitting diode-based colorimeter with tubular porous polypropylene membrane cuvette.

Tian Y, Cheng J, Liu N, Liu X, Zhang X, Chen X Anal Bioanal Chem. 2021; 413(21):5301-5307.

PMID: 34212212 DOI: 10.1007/s00216-021-03503-4.