» Articles » PMID: 32512903

Polymer Optical Fiber-Based Integrated Instrumentation in a Robot-Assisted Rehabilitation Smart Environment: A Proof of Concept

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Jun 10
PMID 32512903
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Advances in robotic systems for rehabilitation purposes have led to the development of specialized robot-assisted rehabilitation clinics. In addition, advantageous features of polymer optical fiber (POF) sensors such as light weight, multiplexing capabilities, electromagnetic field immunity and flexibility have resulted in the widespread use of POF sensors in many areas. Considering this background, this paper presents an integrated POF intensity variation-based sensor system for the instrumentation of different devices. We consider different scenarios for physical rehabilitation, resembling a clinic for robot-assisted rehabilitation. Thus, a multiplexing technique for POF intensity variation-based sensors was applied in which an orthosis for flexion/extension movement, a modular exoskeleton for gait assistance and a treadmill were instrumented with POF angle and force sensors, where all the sensors were integrated in the same POF system. In addition, wearable sensors for gait analysis and physiological parameter monitoring were also proposed and applied in gait exercises. The results show the feasibility of the sensors and methods proposed, where, after the characterization of each sensor, the system was implemented with three volunteers: one for the orthosis on the flexion/extension movements, one for the exoskeleton for gait assistance and the other for the free gait analysis using the proposed wearable POF sensors. To the authors' best knowledge, this is the first time that optical fiber sensors have been used as a multiplexed and integrated solution for the simultaneous assessment of different robotic devices and rehabilitation protocols, where such an approach results in a compact, fully integrated and low-cost system, which can be readily employed in any clinical environment.

Citing Articles

A 1 × 8 Optical Splitter Based on Polycarbonate Multicore Polymer Optical Fibers.

Lanziano L, Sherf I, Malka D Sensors (Basel). 2024; 24(15).

PMID: 39124110 PMC: 11315036. DOI: 10.3390/s24155063.


A Review of Wearable Optical Fiber Sensors for Rehabilitation Monitoring.

Li X, Li Y, Wei H, Wang C, Liu B Sensors (Basel). 2024; 24(11).

PMID: 38894393 PMC: 11175184. DOI: 10.3390/s24113602.


Wearable Optical Fiber Sensors in Medical Monitoring Applications: A Review.

Zhang X, Wang C, Zheng T, Wu H, Wu Q, Wang Y Sensors (Basel). 2023; 23(15).

PMID: 37571457 PMC: 10422468. DOI: 10.3390/s23156671.


Promoting Regional Economic Transformation Forecast Based on Intelligent Computing Technology.

Cai H Comput Intell Neurosci. 2022; 2022:1835376.

PMID: 35281198 PMC: 8916862. DOI: 10.1155/2022/1835376.


Lower Limb Exoskeleton Gait Planning Based on Crutch and Human-Machine Foot Combined Center of Pressure.

Yang W, Zhang J, Zhang S, Yang C Sensors (Basel). 2020; 20(24).

PMID: 33339443 PMC: 7766720. DOI: 10.3390/s20247216.

References
1.
Leal-Junior A, Theodosiou A, Diaz C, Marques C, Pontes M, Kalli K . Fiber Bragg Gratings in CYTOP Fibers Embedded in a 3D-Printed Flexible Support for Assessment of Human⁻Robot Interaction Forces. Materials (Basel). 2018; 11(11). PMC: 6266500. DOI: 10.3390/ma11112305. View

2.
Dos Santos W, Nogueira S, de Oliveira G, Pena G, Siqueira A . Design and evaluation of a modular lower limb exoskeleton for rehabilitation. IEEE Int Conf Rehabil Robot. 2017; 2017:447-451. DOI: 10.1109/ICORR.2017.8009288. View

3.
Leal-Junior A, Theodosiou A, Frizera-Neto A, Pontes M, Shafir E, Palchik O . Characterization of a new polymer optical fiber with enhanced sensing capabilities using a Bragg grating. Opt Lett. 2018; 43(19):4799-4802. DOI: 10.1364/OL.43.004799. View

4.
Kwakkel G, Kollen B, Krebs H . Effects of robot-assisted therapy on upper limb recovery after stroke: a systematic review. Neurorehabil Neural Repair. 2007; 22(2):111-21. PMC: 2730506. DOI: 10.1177/1545968307305457. View

5.
Krebs H, Hogan N . Robotic therapy: the tipping point. Am J Phys Med Rehabil. 2012; 91(11 Suppl 3):S290-7. PMC: 3480667. DOI: 10.1097/PHM.0b013e31826bcd80. View