» Articles » PMID: 32418302

A Pilot Non-inferiority Randomized Controlled Trial to Assess Automatic Adjustments of Insulin Doses in Adolescents with Type 1 Diabetes on Multiple Daily Injections Therapy

Overview
Publisher Wiley
Date 2020 May 18
PMID 32418302
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Multiple daily injections (MDI) therapy for type 1 diabetes involves basal and bolus insulin doses. Non-optimal insulin doses contribute to the lack of satisfactory glycemic control. We aimed to evaluate the feasibility of an algorithm that optimizes daily basal and bolus doses using glucose monitoring systems for MDI therapy users.

Methods: We performed a pilot, non-inferiority, randomized, parallel study at a diabetes camp comparing basal-bolus insulin dose adjustments made by camp physicians (PA) and a learning algorithm (LA), in children and adolescents on MDI therapy. Participants wore a glucose sensor and underwent 11 days of daily dose adjustments in either arm. Algorithm adjustments were reviewed and approved by a physician. The last 7 days were examined for outcomes.

Results: Twenty-one youths (age 13.3 [SD, 3.7] years; 13 females; HbA1c 8.6% [SD, 1.8]) were randomized to either group (LA [n = 10] or PA [n = 11]). The algorithm made 293 adjustments with a 92% acceptance rate from the camp physicians. In the last 7 days, the time in target glucose (3.9-10 mmol/L) in LA (39.5%, SD, 20.7) was similar to PA (38.4%, SD, 15.6) (P = .89). The number of hypoglycemic events per day in LA (0.3, IQR, [0.1-0.6]) was similar to PA (0.2, IQR, [0.0-0.4]) (P = .42). There was no incidence of severe hypoglycemia nor ketoacidosis.

Conclusions: In this pilot study, glycemic outcomes in the LA group were similar to the PA group. This algorithm has the potential to facilitate MDI therapy, and longer and larger studies are warranted.

Citing Articles

The Application of Continuous Glucose Monitoring Endpoints in Clinical Research: Analysis of Trends and Review of Challenges.

Bevan A, Ellis G, Eskandarian M, Garrisi D J Diabetes Sci Technol. 2024; 19322968241301800.

PMID: 39605250 PMC: 11603422. DOI: 10.1177/19322968241301800.


Applications of Clinical Decision Support Systems in Diabetes Care: Scoping Review.

Huang S, Liang Y, Li J, Li X J Med Internet Res. 2023; 25:e51024.

PMID: 38064249 PMC: 10746969. DOI: 10.2196/51024.


Titration of Long-Acting Insulin Using Continuous Glucose Monitoring and Smart Insulin Pens in Type 1 Diabetes: A Model-Based Carbohydrate-Free Approach.

El Fathi A, Fabris C, Breton M Front Endocrinol (Lausanne). 2022; 12:795895.

PMID: 35082757 PMC: 8785345. DOI: 10.3389/fendo.2021.795895.