Impact of Device Landing Zone Calcification Patterns on Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement with Different Next-generation Devices

Abstract

Objective: Residual paravalvular regurgitation (PVR) has been associated to adverse outcomes after transcatheter aortic valve replacement (TAVR). This study sought to evaluate the impact of device landing zone (DLZ) calcification on residual PVR after TAVR with different next-generation transcatheter heart valves.

Methods: 642 patients underwent TAVR with a SAPIEN 3 (S3; n=292), ACURATE (NEO; n=166), Evolut R (ER; n=132) or Lotus (n=52). Extent, location and asymmetry of DLZ calcification were assessed from contrast-enhanced CT imaging and correlated to PVR at discharge.

Results: PVR was ≥moderate in 0.7% of S3 patients, 9.6% of NEO patients, 9.8% of ER patients and 0% of Lotus patients (p<0.001), and these differences remained after matching for total DLZ calcium volume. The amount of DLZ calcium was significantly related to the degree of PVR in patients treated with S3 (p=0.045), NEO (p=0.004) and ER (p<0.001), but not in Lotus patients (p=0.698). The incidence of PVR ≥moderate increased significantly over the tertiles of DLZ calcium volume (p=0.046). On multivariable analysis, calcification of the aortic valve cusps, LVOT calcification and the use of self-expanding transcatheter aortic valve implantation (TAVI) prostheses emerged as predictors of PVR.

Conclusions: The susceptibility to PVR depending on the amount of calcium was mainly observed in self-expanding TAVI prostheses. Thus, DLZ calcification is an important factor to be considered in prosthesis selection for each individual patient, keeping in mind the trade-off between PVR reduction, risk of new pacemaker implantation and unfavourable valve ha emodynamics.

Citing Articles

Real world federated learning with a knowledge distilled transformer for cardiac CT imaging.

Tolle M, Garthe P, Scherer C, Seliger J, Leha A, Kruger N NPJ Digit Med. 2025; 8(1):88.

PMID: 39915633 PMC: 11802793. DOI: 10.1038/s41746-025-01434-3.


High implantation of a balloon-expandable valve above the left ventricular outflow calcification improves the prosthetic valve function without increasing complications: a case series.

Onishi K, Mizutani K, Soejima N, Fujita K, Yasuda M, Ueno M Eur Heart J Case Rep. 2025; 9(1):ytaf007.

PMID: 39877479 PMC: 11772999. DOI: 10.1093/ehjcr/ytaf007.


Contemporary Management of the Aortic Valve-Narrative Review of an Evolving Landscape.

Lella S, Ferrell B, Sugiura T J Clin Med. 2025; 14(1.

PMID: 39797217 PMC: 11722002. DOI: 10.3390/jcm14010134.


Three-Year Outcomes With a Supra-Annular, Self-Expanding Bioprosthesis and a Pericardial Wrap-The FORWARD PRO Study.

Van Mieghem N, Windecker S, Manoharan G, Lancellotti P, Tamburino C, Kornowski R Catheter Cardiovasc Interv. 2024; 105(3):577-587.

PMID: 39686582 PMC: 11831722. DOI: 10.1002/ccd.31335.


Impact of Nodular Calcifications in the Aortic Annulus and Left Ventricular Outflow Tract on TAVI Outcome with New-Generation Devices.

Gorla R, Oliva O, Poletti E, Finotello A, Morganti S, Zannoni J Rev Cardiovasc Med. 2024; 23(11):358.

PMID: 39076178 PMC: 11269076. DOI: 10.31083/j.rcm2311358.


References
1.
Rodriguez-Gabella T, Voisine P, Puri R, Pibarot P, Rodes-Cabau J . Aortic Bioprosthetic Valve Durability: Incidence, Mechanisms, Predictors, and Management of Surgical and Transcatheter Valve Degeneration. J Am Coll Cardiol. 2017; 70(8):1013-1028. DOI: 10.1016/j.jacc.2017.07.715. View

2.
Pibarot P, Hahn R, Weissman N, Arsenault M, Beaudoin J, Bernier M . Association of Paravalvular Regurgitation With 1-Year Outcomes After Transcatheter Aortic Valve Replacement With the SAPIEN 3 Valve. JAMA Cardiol. 2017; 2(11):1208-1216. PMC: 5710359. DOI: 10.1001/jamacardio.2017.3425. View

3.
Noble S, Stortecky S, Heg D, Tueller D, Jeger R, Toggweiler S . Comparison of procedural and clinical outcomes with Evolut R versus Medtronic CoreValve: a Swiss TAVI registry analysis. EuroIntervention. 2017; 12(18):e2170-e2176. DOI: 10.4244/EIJ-D-16-00677. View

4.
Dayan V, Vignolo G, Soca G, Paganini J, Brusich D, Pibarot P . Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement. JACC Cardiovasc Imaging. 2016; 9(8):924-33. DOI: 10.1016/j.jcmg.2015.10.026. View

5.
Kim W, Renker M, Rolf A, Liebetrau C, Van Linden A, Arsalan M . Accuracy of device landing zone calcium volume measurement with contrast-enhanced multidetector computed tomography. Int J Cardiol. 2018; 263:171-176. DOI: 10.1016/j.ijcard.2018.02.042. View