Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease

Overview
Specialty Gastroenterology
Date 2020 Apr 30
PMID 32348907
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background & Aims: Inter-platform variation in liver stiffness evaluation (LSE) could hinder dissemination and clinical implementation of new ultrasound methods. We aimed to determine whether measurements of liver stiffness by bi-dimensional shear wave elastography (2D-SWE) with a Supersonic Imagine apparatus are comparable to those made by vibration-controlled transient elastography (VCTE).

Methods: We collected data from 1219 consecutive patients with chronic liver disease who underwent LSE by VCTE and 2D-SWE (performed by blinded operators), on the same day, at a single center in France from September 2011 through June 2019. We assessed the ability of liver stiffness value distributions and 2D-SWE performances to identify patients with compensated advanced chronic liver disease (cACLD) according to the Baveno VI criteria, based on VCTE cut-off values.

Results: VCTE and 2D-SWE values correlated (Pearson's correlation coefficient, 0.882; P < .0001; Lin concordance coefficient, 0.846; P < .0001). The median stiffness values were 6.7 kPa with VCTE (interquartile range, 4.8-11.6 kPa) and 7.1 kPa with 2D-SWE (interquartile range, 5.4-11.1 kPa) (P = .736). 2D-SWE values were slightly higher in the low percentiles and lower in the high percentiles; the best match with VCTE values were at approximately 7-9 kPa. The area under the curve of 2D-SWE for identifying of VCTE values below 10 was 0.964 (95% CI, 0.952-0.976) and for VCTE values above 15 kPa was 0.976 (95% CI, 0.963-0.988), with Youden index-associated cut-off values of 9.5 and 13kPa and best accuracy cut-off values of 10 kPa and 14 kPa, respectively. A 2D-SWE cut-off value of 10 kPa detected VCTE values below 10k Pa with 92% sensitivity, 87% specificity, and 91% accuracy.

Conclusions: Measurement of liver stiffness by VCTE or 2D-SWE produces comparable results. 2D-SWE accurately identifies patients with cACLD according to the Baveno VI criteria based on VCTE cut-off values. A 10 kPa 2D-SWE cut-off value can be used to rule out cACLD.

Citing Articles

Correlation of shear wave elastography with liver biopsy in children with Chronic Liver disease.

Imtiaz M, Khaqan M, Mazhar M, Seerat I Pak J Med Sci. 2025; 41(2):585-589.

PMID: 39926653 PMC: 11803800. DOI: 10.12669/pjms.41.2.9886.


Capmatinib-Induced Liver Injury as Emerging Toxicity of MET Inhibitors in Patients With NSCLC Pretreated With Immune Checkpoint Inhibitors.

Sisi M, Vitale G, Fusaroli M, Riefolo M, Giunchi V, DErrico A JTO Clin Res Rep. 2023; 4(9):100563.

PMID: 37745898 PMC: 10511802. DOI: 10.1016/j.jtocrr.2023.100563.


Assessment of compensated advanced chronic liver disease based on serum bile acids in chronic hepatitis B patients.

Chen F, Yao Y, Li Z, Deng L, He R Sci Rep. 2023; 13(1):12834.

PMID: 37553441 PMC: 10409722. DOI: 10.1038/s41598-023-39977-8.


How to Identify Advanced Fibrosis in Adult Patients with Non-Alcoholic Fatty Liver Disease (NAFLD) and Non-Alcoholic Steatohepatitis (NASH) Using Ultrasound Elastography-A Review of the Literature and Proposed Multistep Approach.

Taru M, Neamti L, Taru V, Procopciuc L, Procopet B, Lupsor-Platon M Diagnostics (Basel). 2023; 13(4).

PMID: 36832276 PMC: 9955630. DOI: 10.3390/diagnostics13040788.


Clinical utility of two-dimensional shear-wave elastography in monitoring disease course in autoimmune hepatitis-primary biliary cholangitis overlap syndrome.

Yan Y, Xing X, Wang Y, Wang X, Wang Z, Yang L World J Gastroenterol. 2022; 28(18):2021-2033.

PMID: 35664960 PMC: 9150059. DOI: 10.3748/wjg.v28.i18.2021.