Abstract

Objective: The study aimed to compare and evaluate the accuracy of iPex, Root ZX mini, and Epex Pro Electronic apex locators (EALs) in diagnosing root perforations in both dry and in different wet conditions: 5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), and 17% Ethylenediaminetetraacetic acid (EDTA).

Methods: Thirty extracted, human single rooted mandibular premolars were artificially perforated with a diameter of 1.5 mm in middle third of root. Actual canal lengths (ALs) in millimetre (mm) were evaluated for all teeth up to perforation location, and alginate mould were used to embed the teeth. After this, the electronic measurements were calculated by all EALs up to perforation site using a 20 K-file in both dry and wet canal conditions. Up to the perforation sites, the ALs were subtracted from the electronic length. Statistical analyses were done using One-way ANOVA with post hoc tukey's test for pairwise comparison and the level of significance was set at 0.05.

Results: All three EAL's detected canal perforations which were clinically acceptable. There was significant difference for dry and wet conditions. Most accurate measurement were seen in dry canals for all three EALs. Root ZX mini in dry condition showed most accurate reading and there was a significant difference when compared with other groups. No significance difference was observed in iPex and Epex Pro Apex locator, and between NaOCl and CHX, CHX and EDTA.

Conclusion: Perforations were determined within a clinical acceptable range of 0.03-0.05 mm by all three EALs. Root ZX mini in dry canals gave most accurate measurement. The presence of irrigating solution influenced the accuracy of all the apex locators.

Citing Articles

Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment.

Koc S, Harorli H, Kustarci A BMC Oral Health. 2024; 24(1):953.

PMID: 39152371 PMC: 11328487. DOI: 10.1186/s12903-024-04713-9.


Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An Comparative Study.

Yahya E, Alchalabi A, Alkhalidi E J Int Soc Prev Community Dent. 2024; 14(3):211-217.

PMID: 39055293 PMC: 11268530. DOI: 10.4103/jispcd.jispcd_192_23.


Accuracy of an Electronic Apex Locator (EAL) in Measuring the Working Length of Root Canals in Comparison With Radiographs: An In Vivo Study.

Bhagat E, Agnihotri Y, Das A, Das S, Panda S, Hota S Cureus. 2024; 16(5):e60283.

PMID: 38872664 PMC: 11173343. DOI: 10.7759/cureus.60283.


The Accuracy of Three Apex Locators in Determining the Location of Strip Root Perforation in Different Environments.

Shekarchizade N, Farhad A, Khalifezade S Iran Endod J. 2023; 16(3):184-188.

PMID: 36704395 PMC: 9735256. DOI: 10.22037/iej.v16i3.32515.


The Effect of Long Service Life on the Accuracy of Dentaport ZX Electronic Apex Locator.

Parirokh M, Manochehrifar H, Shahravan A, Hosseini H, Samanipoor S Iran Endod J. 2023; 17(4):195-199.

PMID: 36703688 PMC: 9868994. DOI: 10.22037/iej.v17i4.34623.


References
1.
Stober E, Duran-Sindreu F, Mercade M, Vera J, Bueno R, Roig M . An evaluation of root ZX and iPex apex locators: an in vivo study. J Endod. 2011; 37(5):608-10. DOI: 10.1016/j.joen.2011.02.002. View

2.
Alhadainy H . Root perforations. A review of literature. Oral Surg Oral Med Oral Pathol. 1994; 78(3):368-74. DOI: 10.1016/0030-4220(94)90070-1. View

3.
Altunbas D, Kustarci A, Toyoglu M . The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations. J Endod. 2017; 43(3):439-442. DOI: 10.1016/j.joen.2016.10.031. View

4.
Cunha DAssuncao F, Sousa J, Felinto K, de Medeiros T, Leite D, de Lucena R . Accuracy and repeatability of 3 apex locators in locating root canal perforations: an ex vivo study. J Endod. 2014; 40(8):1241-4. DOI: 10.1016/j.joen.2014.02.004. View

5.
Li Y, Zhou Z, Zheng Y, Gan N, Tang Y, Li R . [Accuracy of three different electronic apex locators in determination of perforation with various conditions in vitro]. Hua Xi Kou Qiang Yi Xue Za Zhi. 2011; 29(3):272-5. View