» Articles » PMID: 32287710

Analysis of the Parameters of Respiration Patterns Extracted from Thermal Image Sequences

Overview
Date 2020 Apr 15
PMID 32287710
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Remote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably estimated from signals recorded using a portable thermal camera. The size of the camera and efficiency of the methods allow the implementation of this method in smart glasses.

Citing Articles

Thermal Cameras for Continuous and Contactless Respiration Monitoring.

Alves R, van Meulen F, Overeem S, Zinger S, Stuijk S Sensors (Basel). 2025; 24(24.

PMID: 39771853 PMC: 11679429. DOI: 10.3390/s24248118.


Continuous Critical Respiratory Parameter Measurements Using a Single Low-Cost Relative Humidity Sensor: Evaluation Study.

Vaussenat F, Bhattacharya A, Payette J, Benavides-Guerrero J, Perrotton A, Gerlein L JMIR Biomed Eng. 2024; 8:e47146.

PMID: 38875670 PMC: 11041423. DOI: 10.2196/47146.


Thermal Image Processing for Respiratory Estimation from Cubical Data with Expandable Depth.

Szankin M, Kwasniewska A, Ruminski J J Imaging. 2023; 9(9).

PMID: 37754948 PMC: 10532126. DOI: 10.3390/jimaging9090184.


Face with Mask Detection in Thermal Images Using Deep Neural Networks.

Glowacka N, Ruminski J Sensors (Basel). 2021; 21(19).

PMID: 34640705 PMC: 8512205. DOI: 10.3390/s21196387.


Motion Assessment for Accelerometric and Heart Rate Cycling Data Analysis.

Charvatova H, Prochazka A, Vysata O Sensors (Basel). 2020; 20(5).

PMID: 32164235 PMC: 7085619. DOI: 10.3390/s20051523.

References
1.
Murthy J, van Jaarsveld J, Fei J, Pavlidis I, Harrykissoon R, Lucke J . Thermal infrared imaging: a novel method to monitor airflow during polysomnography. Sleep. 2009; 32(11):1521-7. PMC: 2768959. DOI: 10.1093/sleep/32.11.1521. View

2.
Eckert D, Jordan A, Merchia P, Malhotra A . Central sleep apnea: Pathophysiology and treatment. Chest. 2007; 131(2):595-607. PMC: 2287191. DOI: 10.1378/chest.06.2287. View

3.
Duong D, Shastri D, Tsiamyrtzis P, Pavlidis I . Spatiotemporal reconstruction of the breathing function. Med Image Comput Comput Assist Interv. 2013; 15(Pt 1):149-56. DOI: 10.1007/978-3-642-33415-3_19. View

4.
Cretikos M, Bellomo R, Hillman K, Chen J, Finfer S, Flabouris A . Respiratory rate: the neglected vital sign. Med J Aust. 2008; 188(11):657-9. DOI: 10.5694/j.1326-5377.2008.tb01825.x. View

5.
Ruminski J, Kaczmarek M, Renkielska A, Nowakowski A . Thermal parametric imaging in the evaluation of skin burn depth. IEEE Trans Biomed Eng. 2007; 54(2):303-12. DOI: 10.1109/TBME.2006.886607. View