» Articles » PMID: 32284188

Marginal Adaptation of Zirconia Complete-coverage Fixed Dental Restorations Made from Digital Scans or Conventional Impressions: A Systematic Review and Meta-analysis

Overview
Journal J Prosthet Dent
Specialty Dentistry
Date 2020 Apr 15
PMID 32284188
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Statement Of Problem: Intraoral scanners have been increasingly used in recent years. However, the accuracy of digital scans as it affects marginal adaptation is unclear.

Purpose: The purpose of this systematic review and meta-analysis was to compare the marginal adaptation of single-unit zirconia crowns fabricated with digital scans or with conventional impressions.

Material And Methods: The electronic databases PubMed (MEDLINE), Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science (ISI), Scopus, and EMBASE were searched and complemented by a manual search. Risks of bias were assessed by using a modified methodological index for nonrandomized studies (MINORS). Mean ±standard deviation (SD) values of marginal accuracy of studies were extracted for both methods. Mean marginal difference and 95% confidence interval (CI) were calculated to evaluate the marginal accuracy of each method. Pooled data were statistically analyzed by using a random-effect model.

Results: Seventeen studies were used to perform the meta-analysis. Subgroup analysis was performed based on intraoral scanners. Standardized mean marginal difference and 95% CI of each subgroup were as follows: Lava: -0.85 μm (95% CI: -1.67, -0.03) (P=.043); CEREC: -1.32 μm (95% CI: -2.06, -0.59) (P<.001); iTero: -0.44 μm (95% CI: -1.35, 0.47) (P=.338); TRIOS: -1.26 μm (95% CI: -2.02, -0.51) (P=.001); unknown scanner: -0.21 μm (95% CI: -1.14, 0.72); all studies: -0.89 μm (95% CI: -1.24, -0.54) (P<.001).

Conclusions: Digital scanning of prepared teeth for single-unit zirconia restorations resulted in better marginal accuracy than conventional techniques using elastomeric impression materials.

Citing Articles

Complete Digital Workflow for Evaluation of the Three-Dimensional Monson's Sphere Using Digital Scanning.

Wen C, Wang H, Muhetaer H, Xie F, Han R, Wu J Clin Exp Dent Res. 2025; 11(1):e70063.

PMID: 40066508 PMC: 11894269. DOI: 10.1002/cre2.70063.


Reliability of the digital functionally generated path technique for assessing occlusal interferences and adjusting CAD-CAM zirconia crowns: an in vivo study.

Saad S, Shalaby Y, Azer A BMC Oral Health. 2024; 24(1):1425.

PMID: 39578771 PMC: 11583458. DOI: 10.1186/s12903-024-05202-9.


Digital impression (intraoral scanners) and factors affecting its accuracy - an insight into knowledge and awareness amongst graduates, and clinical practitioners.

Alqahtani S, Chaturvedi S, Alahmari M, Alaleyani A, Alqahtani A, Sahal A BMC Oral Health. 2024; 24(1):1323.

PMID: 39478561 PMC: 11524012. DOI: 10.1186/s12903-024-05075-y.


Evaluating the accuracy of CEREC intraoral scanners for inlay restorations: impact of adjacent tooth materials.

Kwon Y, Kim J, Park J, Son S BMC Oral Health. 2024; 24(1):1033.

PMID: 39227885 PMC: 11370093. DOI: 10.1186/s12903-024-04794-6.


Zirconia-ceramic versus metal-ceramic implant-supported multiunit fixed dental prostheses: A systematic review and meta-analysis.

Tabarak N, Srivastava G, Padhiary S, Manisha J, Choudhury G Dent Res J (Isfahan). 2024; 21:5.

PMID: 38425320 PMC: 10899163.