Abstract

The purpose of this study was to evaluate the accuracy of dental three-dimensional (3D) scanners according to the types of teeth. A computer-aided design (CAD) reference model (CRM) was obtained by scanning the reference typodont model using a high-precision industrial scanner (Solutionix C500, MEDIT). In addition, a CAD test model (CTM) was obtained using seven types of dental 3D scanners (desktop scanners (E1 and DOF Freedom HD) and intraoral scanners (CS3500, CS3600, Trios2, Trios3, and i500)). The 3D inspection software (Geomagic control X, 3DSystems) was used to segment the CRM according to the types of teeth and to superimpose the CTM based on the segmented teeth. The 3D accuracy of the scanner was then analyzed according to the types of teeth. One-way analysis of variance (ANOVA) was used to compare the differences according to the types of teeth in statistical analysis, and the Tukey HSD test was used for post hoc testing (α = 0.05). Both desktop and intraoral scanners showed significant differences in accuracy according to the types of teeth ( < 0.001), and the accuracy of intraoral scanners tended to get worse from anterior to posterior. Therefore, when scanning a complete arch using an intraoral scanner, the clinician should consider the tendency for the accuracy to decrease from anterior to posterior.

Citing Articles

Influence of different dental scenarios on the accuracy of computerized optical impressions: an in vitro pilot study.

Saravi B, Paffenholz C, Hazard D, Kohal R, Patzelt S Clin Oral Investig. 2025; 29(3):162.

PMID: 40016551 PMC: 11868131. DOI: 10.1007/s00784-025-06245-0.


Comparisons of precision and trueness of digital dental casts produced by desktop scanners and intraoral scanners.

Chuang C, Cheng F, Chen M, Lin W, Chiang C J Dent Sci. 2025; 20(1):137-146.

PMID: 39873032 PMC: 11763548. DOI: 10.1016/j.jds.2024.09.016.


Evaluation of the effect of different core substrates on the accuracy of intraoral scanners.

Khoshkhahesh M, Enteghad S, Aghasadeghi K, Farzin M, Taghva M, Mosadad S Clin Exp Dent Res. 2024; 10(3):e899.

PMID: 38752461 PMC: 11097246. DOI: 10.1002/cre2.899.


Comparative analysis on efficiency and accuracy of parallel confocal microscopy and three-dimensional in motion video with triangulation technology-based intraoral scanner under influence of moisture and mouth opening - A crossover clinical trial.

Sindhu J, Maiti S, Nallaswamy D J Indian Prosthodont Soc. 2023; 23(3):234-243.

PMID: 37929362 PMC: 10467319. DOI: 10.4103/jips.jips_65_23.


Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study.

Kim E, Wada J, Sakamoto K, Ishioka Y, Arai Y, Murakami N J Clin Med. 2022; 11(24).

PMID: 36556008 PMC: 9783230. DOI: 10.3390/jcm11247392.


References
1.
Anh J, Park J, Chun Y, Kim M, Kim M . A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction. Korean J Orthod. 2016; 46(1):3-12. PMC: 4751299. DOI: 10.4041/kjod.2016.46.1.3. View

2.
Fukazawa S, Odaira C, Kondo H . Investigation of accuracy and reproducibility of abutment position by intraoral scanners. J Prosthodont Res. 2017; 61(4):450-459. DOI: 10.1016/j.jpor.2017.01.005. View

3.
Ferrini F, Cappare P, Vinci R, Gherlone E, Sannino G . Digital versus Traditional Workflow for Posterior Maxillary Rehabilitations Supported by One Straight and One Tilted Implant: A 3-Year Prospective Comparative Study. Biomed Res Int. 2018; 2018:4149107. PMC: 6252190. DOI: 10.1155/2018/4149107. View

4.
Son K, Lee W, Lee K . Prediction of the learning curves of 2 dental CAD software programs. J Prosthet Dent. 2018; 121(1):95-100. DOI: 10.1016/j.prosdent.2018.01.004. View

5.
Jeong I, Lee J, Jeon J, Kim J, Kim H, Kim W . Accuracy of complete-arch model using an intraoral video scanner: An in vitro study. J Prosthet Dent. 2016; 115(6):755-9. DOI: 10.1016/j.prosdent.2015.11.007. View