» Articles » PMID: 32188068

Low Dose CT Image Reconstruction Based on Structure Tensor Total Variation Using Accelerated Fast Iterative Shrinkage Thresholding Algorithm

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Mar 20
PMID 32188068
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Low dose computed tomography (CT) has drawn much attention in the medical imaging field because of its ability to reduce the radiation dose. Recently, statistical iterative reconstruction (SIR) with total variation (TV) penalty has been developed to low dose CT image reconstruction. Nevertheless, the TV penalty has the drawback of creating blocky effects in the reconstructed images. To overcome the limitations of TV, in this paper we firstly introduce the structure tensor total variation (STV) penalty into SIR framework for low dose CT image reconstruction. Then, an accelerated fast iterative shrinkage thresholding algorithm (AFISTA) is developed to minimize the objective function. The proposed AFISTA reconstruction algorithm was evaluated using numerical simulated low dose projection based on two CT images and realistic low dose projection data of a sheep lung CT perfusion. The experimental results demonstrated that our proposed STV-based algorithm outperform FBP and TV-based algorithm in terms of removing noise and restraining blocky effects.

Citing Articles

Computed Tomography Imaging under Artificial Intelligence Reconstruction Algorithm Used in Recovery of Sports Injury of the Knee Anterior Cruciate Ligament.

Zhang H, Zheng H, Deng R, Luo K, Duan S Contrast Media Mol Imaging. 2022; 2022:1199841.

PMID: 35685654 PMC: 9167137. DOI: 10.1155/2022/1199841.


CT Image Features Based on the Reconstruction Algorithm for Continuous Blood Purification Combined with Nursing Intervention in the Treatment of Severe Acute Pancreatitis.

Liu Y, Gu M, Liu L, Cui L, Xing A Contrast Media Mol Imaging. 2022; 2022:2622316.

PMID: 35414803 PMC: 8979709. DOI: 10.1155/2022/2622316.


Mutual Information-Based Non-Local Total Variation Denoiser for Low-Dose Cone-Beam Computed Tomography.

Lee H, Sung J, Choi Y, Kim J, Lee I Front Oncol. 2021; 11:751057.

PMID: 34745978 PMC: 8567105. DOI: 10.3389/fonc.2021.751057.


A Novel Singular Value Decomposition-Based Denoising Method in 4-Dimensional Computed Tomography of the Brain in Stroke Patients with Statistical Evaluation.

Yang W, Hong J, Kim J, Paik S, Lee S, Park J Sensors (Basel). 2020; 20(11).

PMID: 32481740 PMC: 7309118. DOI: 10.3390/s20113063.

References
1.
Sidky E, Pan X . Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol. 2008; 53(17):4777-807. PMC: 2630711. DOI: 10.1088/0031-9155/53/17/021. View

2.
Shangguan H, Zhang Q, Liu Y, Cui X, Bai Y, Gui Z . Low-dose CT statistical iterative reconstruction via modified MRF regularization. Comput Methods Programs Biomed. 2015; 123:129-41. DOI: 10.1016/j.cmpb.2015.10.004. View

3.
Zeng D, Gao Y, Huang J, Bian Z, Zhang H, Lu L . Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization. Comput Med Imaging Graph. 2016; 53:19-29. DOI: 10.1016/j.compmedimag.2016.07.002. View

4.
Erdogan H, Fessler J . Ordered subsets algorithms for transmission tomography. Phys Med Biol. 1999; 44(11):2835-51. DOI: 10.1088/0031-9155/44/11/311. View

5.
Gong C, Han C, Gan G, Deng Z, Zhou Y, Yi J . Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization. Phys Med Biol. 2017; 62(7):2612-2635. DOI: 10.1088/1361-6560/aa5d40. View