» Articles » PMID: 32133235

SNR Enhancement in Brillouin Microspectroscopy Using Spectrum Reconstruction

Overview
Specialty Radiology
Date 2020 Mar 6
PMID 32133235
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Brillouin spectroscopy can suffer from low signal-to-noise ratios (SNRs). Such low SNRs can render common data analysis protocols unreliable, especially for SNRs below ∼10. In this work we exploit two denoising algorithms, namely maximum entropy reconstruction (MER) and wavelet analysis (WA), to improve the accuracy and precision in determination of Brillouin shifts and linewidth. Algorithm performance is quantified using Monte-Carlo simulations and benchmarked against the Cramér-Rao lower bound. Superior estimation results are demonstrated even at low SNRs (≥ 1). Denoising is furthermore applied to experimental Brillouin spectra of distilled water at room temperature, allowing the speed of sound in water to be extracted. Experimental and theoretical values were found to be consistent to within ±1% at unity SNR.

Citing Articles

Precision comparison of intensity ratios and area ratios in spectral analysis.

Hagiwara Y, Kuwatani T Sci Rep. 2024; 14(1):22898.

PMID: 39406767 PMC: 11480322. DOI: 10.1038/s41598-024-71653-3.


Brillouin microscopy.

Kabakova I, Zhang J, Xiang Y, Caponi S, Bilenca A, Guck J Nat Rev Methods Primers. 2024; 4.

PMID: 39391288 PMC: 11465583. DOI: 10.1038/s43586-023-00286-z.


Background-free fibre optic Brillouin probe for remote mapping of micromechanics.

Xiang Y, Basirun C, Chou J, Warkiani M, Torok P, Wang Y Biomed Opt Express. 2020; 11(11):6687-6698.

PMID: 33282517 PMC: 7687937. DOI: 10.1364/BOE.404535.


Recent progress and current opinions in Brillouin microscopy for life science applications.

Antonacci G, Beck T, Bilenca A, Czarske J, Elsayad K, Guck J Biophys Rev. 2020; 12(3):615-624.

PMID: 32458371 PMC: 7311586. DOI: 10.1007/s12551-020-00701-9.


Precision and informational limits in inelastic optical spectroscopy.

Torok P, Foreman M Sci Rep. 2019; 9(1):6140.

PMID: 30992485 PMC: 6468005. DOI: 10.1038/s41598-019-42619-7.

References
1.
Ballmann C, Thompson J, Traverso A, Meng Z, Scully M, Yakovlev V . Stimulated Brillouin Scattering Microscopic Imaging. Sci Rep. 2015; 5:18139. PMC: 4686920. DOI: 10.1038/srep18139. View

2.
Berglund A, McMahon M, McClelland J, Liddle J . Fast, bias-free algorithm for tracking single particles with variable size and shape. Opt Express. 2008; 16(18):14064-75. DOI: 10.1364/oe.16.014064. View

3.
Karampatzakis A, Song C, Allsopp L, Filloux A, Rice S, Cohen Y . Probing the internal micromechanical properties of biofilms by Brillouin imaging. NPJ Biofilms Microbiomes. 2017; 3:20. PMC: 5591272. DOI: 10.1038/s41522-017-0028-z. View

4.
Ram S, Ward E, Ober R . Beyond Rayleigh's criterion: a resolution measure with application to single-molecule microscopy. Proc Natl Acad Sci U S A. 2006; 103(12):4457-62. PMC: 1450193. DOI: 10.1073/pnas.0508047103. View

5.
Antonacci G, Pedrigi R, Kondiboyina A, Mehta V, De Silva R, Paterson C . Quantification of plaque stiffness by Brillouin microscopy in experimental thin cap fibroatheroma. J R Soc Interface. 2015; 12(112). PMC: 4685854. DOI: 10.1098/rsif.2015.0843. View