A Prototype VP-PET Imaging System Based on Highly Pixelated CdZnTe Detectors

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Mar 4
PMID 32120956
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

We investigated a prototype virtual-pinhole positron emission tomography (PET) system for small-animal imaging applications. The PET detector modules were made up of 1.3 mm lutetium-yttrium oxyorthosilicate (LYSO) arrays, and the insert detectors consisted of 0.6 mm pixelated cadmium zinc telluride (CdZnTe). To validate the imaging experiment, we did a Monte Carlo simulation for the virtual-pinhole PET (VP-PET) system in the Geant4 Application for Emission Tomography (GATE). For a point source of Na with a 0.5 mm diameter, the filtered back-projection algorithm-reconstructed PET image showed a resolution of 0.7 mm full-width-at-half-maximum. The system sensitivity was 0.46 cps/kBq at the center of the field view of the PET system with a source activity of 0.925 MBq and an energy window of 350 to 650 keV. A rod source phantom and a Derenzo phantom with F were also simulated to investigate the PET imaging ability. GATE simulation indicated that sources with 0.5 mm diameter could be clearly detected using 0.6 mm pixelated CdZnTe detectors as insert devices in a VP-PET system.

Citing Articles

Experimental Evaluation of a 3-D CZT Imaging Spectrometer for Potential Use in Compton-Enhanced PET Imaging.

Jin Y, Streicher M, Yang H, Brown S, He Z, Meng L IEEE Trans Radiat Plasma Med Sci. 2023; 7(1):18-32.

PMID: 38106623 PMC: 10723109. DOI: 10.1109/trpms.2022.3200010.

References
1.
Kastis G, Wu M, Balzer S, Wilson D, Furenlid L, Stevenson G . Tomographic Small-Animal Imaging Using a High-Resolution Semiconductor Camera. IEEE Nucl Sci Symp Conf Rec (1997). 2015; 49(1):172-175. PMC: 4643294. DOI: 10.1109/TNS.2002.998747. View

2.
Gu Y, Matteson J, Skelton R, Deal A, Stephan E, Duttweiler F . Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET. Phys Med Biol. 2011; 56(6):1563-84. PMC: 3274175. DOI: 10.1088/0031-9155/56/6/004. View

3.
Lamare F, Turzo A, Bizais Y, Cheze Le Rest C, Visvikis D . Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE. Phys Med Biol. 2006; 51(4):943-62. DOI: 10.1088/0031-9155/51/4/013. View

4.
Qi J, Yang Y, Zhou J, Wu Y, Cherry S . Experimental assessment of resolution improvement of a zoom-in PET. Phys Med Biol. 2011; 56(17):N165-74. DOI: 10.1088/0031-9155/56/17/N01. View

5.
Jan S, Santin G, Strul D, Staelens S, Assie K, Autret D . GATE: a simulation toolkit for PET and SPECT. Phys Med Biol. 2004; 49(19):4543-61. PMC: 3267383. DOI: 10.1088/0031-9155/49/19/007. View