» Articles » PMID: 32111855

Digital Scanning is More Accurate Than Using a Periodontal Probe to Measure the Keratinized Tissue Width

Overview
Journal Sci Rep
Specialty Science
Date 2020 Mar 1
PMID 32111855
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

This study aimed to compare the accuracy and reliability of digital versus conventional clinical measurements of the width of keratinized tissue. To this end, the keratinized tissue width was measured at 110 tooth sites in 5 pig jaws. The measurements were made at each site using three-dimensional (3D) scanned images and a periodontal probe. The actual keratinized tissue width was subsequently measured on histologic slides prepared from the same sites, and differences between the histologic slides and the digital and clinical measurements were analyzed to determine their accuracy in two measurement rounds. Furthermore, intrarater and interrater reliabilities were evaluated using the intraclass correlation coefficient (ICC). Here we show that the mean differences (and lower/upper limits of agreement) between the histologic and the digital/clinical measurements were 0.10 mm (-1.34/1.54 mm) and 1.11 mm (-0.69/2.92 mm), respectively, in the first round of measurements (p < 0.01), and 0.04 mm (-1.52/1.59 mm) and 1.05 mm (-0.37/2.48 mm) in the second round of measurements (p < 0.01). Moreover, we found that the intrarater reliability was higher for the digital measurements (ICC = 0.97, confidence interval [CI] = 0.96-0.97) than for the clinical measurements (ICC = 0.87, CI = 0.86-0.89; p < 0.01). Taken together, our results demonstrate that digital measurements of the keratinized tissue width using 3D scanned images can replace conventional clinical measurements using a periodontal probe since they are more accurate and reliable.

Citing Articles

Novel digital technique for measuring the volumetric healing process of free gingival grafts surrounding dental implants.

Docampo-Vazquez C, Gragera-Alia T, Fernandez-Dominguez M, Zubizarreta-Macho A, Aragoneses-Lamas J Front Dent Med. 2025; 5:1372312.

PMID: 39917676 PMC: 11797868. DOI: 10.3389/fdmed.2024.1372312.


Digital quantification of soft tissue volumetric changes after scaling and root planning.

Vallejos-Juarez I, Fons-Font A, Agustin-Panadero R, Gonzalez-Angulo E, Alonso-Perez-Barquero J, Fons-Badal C Med Oral Patol Oral Cir Bucal. 2024; 29(6):e815-e821.

PMID: 39154251 PMC: 11584964. DOI: 10.4317/medoral.26766.


Revisiting the measurement of keratinized gingiva: a cross-sectional study comparing an intraoral scanner with clinical parameters.

Nalbantoglu A, Yanik D J Periodontal Implant Sci. 2023; 53(5):362-375.

PMID: 37524382 PMC: 10627736. DOI: 10.5051/jpis.2204320216.


Intraoral Scanners for In Vivo 3D Imaging of the Gingiva and the Alveolar Process.

Winkler J, Sculean A, Gkantidis N J Clin Med. 2022; 11(21).

PMID: 36362615 PMC: 9655054. DOI: 10.3390/jcm11216389.


Comparison of the Effectiveness of the Ultrasonic Method and Cone-Beam Computed Tomography Combined with Intraoral Scanning and Prosthetic-Driven Implant Planning Method in Determining the Gingival Phenotype in the Healthy Periodontium.

Bednarz-Tumidajewicz M, Furtak A, Zakrzewska A, Rapala M, Gerreth K, Gedrange T Int J Environ Res Public Health. 2022; 19(19).

PMID: 36231576 PMC: 9566378. DOI: 10.3390/ijerph191912276.


References
1.
Thoma D, Naenni N, Figuero E, Hammerle C, Schwarz F, Jung R . Effects of soft tissue augmentation procedures on peri-implant health or disease: A systematic review and meta-analysis. Clin Oral Implants Res. 2018; 29 Suppl 15:32-49. DOI: 10.1111/clr.13114. View

2.
Bouri Jr A, Bissada N, Al-Zahrani M, Faddoul F, Nouneh I . Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants. 2008; 23(2):323-6. View

3.
ORBAN B . Clinical and histologic study of the surface characteristics of the gingiva. Oral Surg Oral Med Oral Pathol. 1948; 1(9):827-41. DOI: 10.1016/0030-4220(48)90014-0. View

4.
Lang N, Loe H . The relationship between the width of keratinized gingiva and gingival health. J Periodontol. 1972; 43(10):623-7. DOI: 10.1902/jop.1972.43.10.623. View

5.
Grossi S, Dunford R, Ho A, Koch G, Machtei E, Genco R . Sources of error for periodontal probing measurements. J Periodontal Res. 1996; 31(5):330-6. DOI: 10.1111/j.1600-0765.1996.tb00500.x. View