» Articles » PMID: 32109464

Prediction of Pregnancy Loss by Early First Trimester Ultrasound Characteristics

Overview
Publisher Elsevier
Date 2020 Feb 29
PMID 32109464
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Pregnancy loss prediction based on routinely measured ultrasound characteristics is generally aimed toward distinguishing nonviability. Physicians also use ultrasound indicators for patient counseling, and in some cases to decide upon the frequency of follow-up sonograms. To improve clinical utility, allocation of cut-points should be based on clinical data for multiple sonographic characteristics, be specific to gestational week, and be determined by methods that optimize prediction.

Objectives: To identify routinely measured features of the early first trimester ultrasound and the gestational age-specific cut-points that are most predictive of pregnancy loss.

Materials And Methods: This was a secondary analysis of 617 pregnant women enrolled in the Effects of Aspirin in Gestation and Reproduction (EAGeR) trial; all women had 1-2 previous pregnancy losses and no documented infertility. Each participant had a single ultrasound with a detectable fetal heartbeat between 6 weeks 0 days and 8 weeks 6 days. Cut-points for low fetal heart rate and small crown-rump length were separately defined for gestational weeks 6, 7, and 8 to optimize prediction. Identity and log-binomial regression models were used to estimate absolute and relative risks, respectively, and 95% confidence intervals between jointly categorized low fetal heart rate, small crown-rump length, and clinical pregnancy loss. Adjusted models accounted for gestational age at ultrasound in weeks. Missing data were addressed using multiple imputation.

Results: A total of 64 women experienced a clinical pregnancy loss following the first ultrasound (10.4%), 7 were lost to follow-up (1.1%), and 546 women (88.5%) had a live birth. Low fetal heart rate and small crown-rump length (≤122, 123, and 158 bpm; ≤6.0, 8.5, and 10.9 mm for gestational weeks 6, 7, and 8, respectively) were independent predictors of clinical pregnancy loss, with greatest risks observed for pregnancies having both characteristics (relative risk, 2.08; 95% confidence interval, 1.24-2.91). The combination of low fetal heart rate and small crown-rump length was linked to a 16% (95% confidence interval, 9.1-23%) adjusted absolute increase in risk of subsequent loss, from 5.0% (95% confidence interval, 1.5-8.5%) to 21% (95% confidence interval, 15-27%). Abnormal yolk sac diameter or the presence of a subchorionic hemmhorage did not improve prediction of clinical pregnancy loss.

Conclusion: Identified cut-points can be used by physicians for patient counseling, and in some cases to decide upon the frequency of follow-up sonograms. The specified criteria should not be used to diagnose nonviability.

Citing Articles

The predictive value of ultrasound markers for pregnancy outcomes in recurrent pregnancy loss: a retrospective study.

Liu C, Wei X, Wang F Sci Rep. 2024; 14(1):16657.

PMID: 39030360 PMC: 11271540. DOI: 10.1038/s41598-024-67744-w.


Predictive models of miscarriage on the basis of data from a preconception cohort study.

Yland J, Zad Z, Wang T, Wesselink A, Jiang T, Hatch E Fertil Steril. 2024; 122(1):140-149.

PMID: 38604264 PMC: 11651128. DOI: 10.1016/j.fertnstert.2024.04.007.


Biomarkers at 6 weeks' gestation in the prediction of early miscarriage in pregnancy following assisted reproductive technology.

Guo J, Feng Q, Chaemsaithong P, Appiah K, Sahota D, Leung B Acta Obstet Gynecol Scand. 2023; 102(8):1073-1083.

PMID: 37377341 PMC: 10378019. DOI: 10.1111/aogs.14618.


First-Trimester Screening for Miscarriage or Stillbirth-Prediction Model Based on MicroRNA Biomarkers.

Hromadnikova I, Kotlabova K, Krofta L Int J Mol Sci. 2023; 24(12).

PMID: 37373283 PMC: 10299132. DOI: 10.3390/ijms241210137.


Maternal circulating exosomal miR-185-5p levels as a predictive biomarker in patients with recurrent pregnancy loss.

Xiong Y, Fang Z, Dong J, Chen S, Mao J, Zhang W J Assist Reprod Genet. 2023; 40(3):553-566.

PMID: 36745296 PMC: 10033820. DOI: 10.1007/s10815-023-02733-y.


References
1.
Mumford S, Silver R, Sjaarda L, Wactawski-Wende J, Townsend J, Lynch A . Expanded findings from a randomized controlled trial of preconception low-dose aspirin and pregnancy loss. Hum Reprod. 2016; 31(3):657-65. PMC: 4755442. DOI: 10.1093/humrep/dev329. View

2.
Choong S, Rombauts L, Ugoni A, Meagher S . Ultrasound prediction of risk of spontaneous miscarriage in live embryos from assisted conceptions. Ultrasound Obstet Gynecol. 2003; 22(6):571-7. DOI: 10.1002/uog.909. View

3.
Johns J, Hyett J, Jauniaux E . Obstetric outcome after threatened miscarriage with and without a hematoma on ultrasound. Obstet Gynecol. 2003; 102(3):483-7. DOI: 10.1016/s0029-7844(03)00580-5. View

4.
Abu-Yousef M, Bleicher J, Williamson R, Weiner C . Subchorionic hemorrhage: sonographic diagnosis and clinical significance. AJR Am J Roentgenol. 1987; 149(4):737-40. DOI: 10.2214/ajr.149.4.737. View

5.
Bottomley C, Van Belle V, Pexsters A, Papageorghiou A, Mukri F, Kirk E . A model and scoring system to predict outcome of intrauterine pregnancies of uncertain viability. Ultrasound Obstet Gynecol. 2011; 37(5):588-95. DOI: 10.1002/uog.9007. View