» Articles » PMID: 32098323

Miniaturized 0.13-μm CMOS Front-End Analog for AlN PMUT Arrays

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Feb 27
PMID 32098323
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents an analog front-end transceiver for an ultrasound imaging system based on a high-voltage (HV) transmitter, a low-noise front-end amplifier (RX), and a complementary-metal-oxide-semiconductor, aluminum nitride, piezoelectric micromachined ultrasonic transducer (CMOS-AlN-PMUT). The system was designed using the 0.13-μm Silterra CMOS process and the MEMS-on-CMOS platform, which allowed for the implementation of an AlN PMUT on top of the CMOS-integrated circuit. The HV transmitter drives a column of six 80-μm-square PMUTs excited with 32 V in order to generate enough acoustic pressure at a 2.1-mm axial distance. On the reception side, another six 80-μm-square PMUT columns convert the received echo into an electric charge that is amplified by the receiver front-end amplifier. A comparative analysis between a voltage front-end amplifier (VA) based on capacitive integration and a charge-sensitive front-end amplifier (CSA) is presented. Electrical and acoustic experiments successfully demonstrated the functionality of the designed low-power analog front-end circuitry, which outperformed a state-of-the art front-end application-specific integrated circuit (ASIC) in terms of power consumption, noise performance, and area.

Citing Articles

Design of Preamplifier for Ultrasound Transducers.

Choi H Sensors (Basel). 2024; 24(3).

PMID: 38339502 PMC: 10856992. DOI: 10.3390/s24030786.


ScAlN Film-Based Piezoelectric Micromechanical Ultrasonic Transducers with Dual-Ring Structure for Distance Sensing.

Zhang Y, Miao B, Wang G, Zhou H, Zhang S, Hu Y Micromachines (Basel). 2023; 14(3).

PMID: 36984923 PMC: 10051667. DOI: 10.3390/mi14030516.


Piezoelectric Micromachined Ultrasonic Transducers (PMUTs): Performance Metrics, Advancements, and Applications.

Birjis Y, Swaminathan S, Nazemi H, Raj G, Munirathinam P, Abu-Libdeh A Sensors (Basel). 2022; 22(23).

PMID: 36501852 PMC: 9738559. DOI: 10.3390/s22239151.


A Review on VCII Applications in Signal Conditioning for Sensors and Bioelectrical Signals: New Opportunities.

Safari L, Barile G, Stornelli V, Ferri G Sensors (Basel). 2022; 22(9).

PMID: 35591268 PMC: 9101695. DOI: 10.3390/s22093578.


Enhancement of the Transmission Performance of Piezoelectric Micromachined Ultrasound Transducers by Vibration Mode Optimization.

Li P, Fan Z, Duan X, Cui D, Zang J, Zhang Z Micromachines (Basel). 2022; 13(4).

PMID: 35457901 PMC: 9028921. DOI: 10.3390/mi13040596.


References
1.
Jiang X, Lu Y, Tang H, Tsai J, Ng E, Daneman M . Monolithic ultrasound fingerprint sensor. Microsyst Nanoeng. 2019; 3:17059. PMC: 6445013. DOI: 10.1038/micronano.2017.59. View

2.
Janjic J, Tan M, Daeichin V, Noothout E, Chen C, Chen Z . A 2-D Ultrasound Transducer With Front-End ASIC and Low Cable Count for 3-D Forward-Looking Intravascular Imaging: Performance and Characterization. IEEE Trans Ultrason Ferroelectr Freq Control. 2018; 65(10):1832-1844. DOI: 10.1109/TUFFC.2018.2859824. View

3.
Jiang X, Tang H, Lu Y, Ng E, Tsai J, Boser B . Ultrasonic Fingerprint Sensor With Transmit Beamforming Based on a PMUT Array Bonded to CMOS Circuitry. IEEE Trans Ultrason Ferroelectr Freq Control. 2017; 64(9):1401-1408. DOI: 10.1109/TUFFC.2017.2703606. View

4.
Sautto M, Stuart Savoia A, Quaglia F, Caliano G, Mazzanti A . A Comparative Analysis of CMUT Receiving Architectures for the Design Optimization of Integrated Transceiver Front Ends. IEEE Trans Ultrason Ferroelectr Freq Control. 2017; 64(5):826-838. DOI: 10.1109/TUFFC.2017.2668769. View

5.
Tang H, Seo D, Singhal U, Li X, Maharbiz M, Alon E . Miniaturizing Ultrasonic System for Portable Health Care and Fitness. IEEE Trans Biomed Circuits Syst. 2016; 9(6):767-76. DOI: 10.1109/TBCAS.2015.2508439. View