Abstract

Introduction: Total body irradiation (TBI) is a part of the conditioning regimen for bone marrow transplant.At the Royal Marsden (Sutton, UK) and Rigshospitalet (Copenhagen, Denmark), we introduced a step and shoot IMRT (SS IMRT) technique for TBI. This technique requires no equipment other than that used to deliver other external beam radiation. In this paper, we describe this technique and report on data from the two clinics.

Materials And Methods: The patients were positioned supine, supported by vacuum bag(s). The entire body of the patients were CT scanned with 5 mm slices. Multiple multi-leaf collimator (MLC) defined fields were used.In-vivo dosimetry was performed at the Royal Marsden for 113 patients.Calculated doses for 18 adult and 4 paediatric patients from Rigshospitalet were extracted.

Results: The in-vivo data from the Royal Marsden showed that the mean TLD measured dose difference was -1.9% with a standard deviation of 4.5%.SS IMRT plans for 22 patients from Rigshospitalet resulted in mean doses to the brain, lungs and kidneys all within the range of 11.1-11.8 Gy, while the V(12 Gy) was below 5% for the brain, 2% for the lungs and 0% for the kidneys.

Discussion: SS IMRT is feasible for TBI and can deliver targeted doses to the organs at risk.

Citing Articles

Total body irradiation: A transition from a Co-60 treatment unit to an IMRT lateral-field extended-SAD technique.

Kolokotronis A, Brunet-Benkhoucha M, Roussin E, St-Pierre J, Marchand E, Bernard M J Appl Clin Med Phys. 2024; 25(9):e14430.

PMID: 38952071 PMC: 11492311. DOI: 10.1002/acm2.14430.


Global research trends in Total Body Irradiation: a bibliometric analysis.

Alqathami M, Khan M, Yoosuf A Front Oncol. 2024; 14:1370059.

PMID: 38737901 PMC: 11082912. DOI: 10.3389/fonc.2024.1370059.


A novel AP/PA total body irradiation technique using abutting IMRT fields at extended SSD.

Liang X, Li P, Wu Q J Appl Clin Med Phys. 2024; 25(4):e14213.

PMID: 38425126 PMC: 11005982. DOI: 10.1002/acm2.14213.


Commissioning and performance evaluation of commercially available mobile imager for image guided total body irradiation.

Nakaichi T, Okamoto H, Kon M, Takaso K, Aikawa A, Nakamura S J Appl Clin Med Phys. 2022; 24(4):e13865.

PMID: 36573258 PMC: 10113699. DOI: 10.1002/acm2.13865.


Optimised conformal total body irradiation: a heterogeneous practice, so where next?.

Misson-Yates S, Cunningham R, Gonzalez R, Diez P, Clark C Br J Radiol. 2022; 96(1144):20220650.

PMID: 36475820 PMC: 10078861. DOI: 10.1259/bjr.20220650.


References
1.
Wong J, Filippi A, Shbib Dabaja B, Yahalom J, Specht L . Total Body Irradiation: Guidelines from the International Lymphoma Radiation Oncology Group (ILROG). Int J Radiat Oncol Biol Phys. 2018; 101(3):521-529. DOI: 10.1016/j.ijrobp.2018.04.071. View

2.
Broerse J, Bartstra R, van Bekkum D, Van Der Hage M, Zurcher C, van Zwieten M . The carcinogenic risk of high dose total body irradiation in non-human primates. Radiother Oncol. 2000; 54(3):247-53. DOI: 10.1016/s0167-8140(00)00147-x. View

3.
WEINER R, BORTIN M, Gale R, Gluckman E, Kay H, Kolb H . Interstitial pneumonitis after bone marrow transplantation. Assessment of risk factors. Ann Intern Med. 1986; 104(2):168-75. DOI: 10.7326/0003-4819-104-2-168. View

4.
Henslee-Downey P, Abhyankar S, Parrish R, Pati A, Godder K, Neglia W . Use of partially mismatched related donors extends access to allogeneic marrow transplant. Blood. 1997; 89(10):3864-72. View

5.
Igaki H, Karasawa K, Sakamaki H, Saito H, Nakagawa K, Ohtomo K . Renal dysfunction after total-body irradiation. Significance of selective renal shielding blocks. Strahlenther Onkol. 2005; 181(11):704-8. DOI: 10.1007/s00066-005-1405-8. View