Air Kerma Rate Constants for Radionuclides
Overview
Authors
Affiliations
Conversion to SI units requires that the exposure rate constant which was usually quoted in R.h-1.mCi-1.cm2 be replaced by the air kerma rate constant with units m2.Gy.Bq-1.s-1. The conversion factor is derived and air kerma rate constants for 30 radionuclides used in nuclear medicine and brachytherapy are listed. A table for calculation of air kerma rates for other radionuclides is also given. To calculate absorbed dose to tissue, the air kerma rate has to be multiplied by approximately 1.1. A dose equivalent rate constant is thus listed which allows direct calculation of dose equivalent rate to soft tissue without resorting to exposure rate constants tabulated in the special units R.m2.mCi-1.h-1 which should no longer be used.