» Articles » PMID: 32048345

Left and Right Ventricular Function Detection and Myocardial Deformation Analysis in Heart Transplant Patients with Long-time Follow-ups

Overview
Journal J Card Surg
Date 2020 Feb 13
PMID 32048345
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: We try to investigate whether the values of longitudinal strain present differences between the left and right ventricles in long-time follow-ups after heart transplantation (HTx) with dynamic changes in function.

Methods And Results: Follow-up transthoracic echocardiography was performed in 1- and 3-month and 1- and 5-year follow-ups in 50 "healthy" HTx patients and compared with 26 control subjects. The left ventricle with preserved ejection fraction evaluated by biplane Simpson (control group [CG] vs HT; P > .05) had an obvious reduction in global (CG: -20.49 ± 2.38 vs heart transplant 1 month [HT1m]: -13.06 ± 2.86, heart transplant 3 month [HT3m]: -13.61 ± 2.61, heart transplant 1 year [HT1y]: -13.69 ± 4.56, heart transplant 5 year [HT5y]: -14.41 ± 4.54; P < .001) and horizontal segmental (basal, mid, apical) (P < .001) together with chamber segmental (apical 4-chamber, apical 3-chamber, apical 2-chamber) (P < .001) average strain values. The right ventricle with reduced ventricular function measured by tissue Doppler imaging S' and tricuspid annular plane systolic excursion had a more distinctive reduction in global (CG: -24.53 ± 4.20 vs HT1m: -12.94 ± 5.03, HT3m: -13.68 ± 4.35, HT1y: -14.95 ± 7.50, HT5y: -15.20 ± 6.15; P < .001) with segmental lateral (P < .001) strain values. There were not any significant changes between 1- and 3-month follow-ups of all the values (P > .05). But it could be seen that values increased in 1- and 5-year follow-ups compared with the baseline of 1- and 3-month follow-ups (P < .05). The global and segmental strain of the right ventricle decreased more than that of the left ventricle in all HTx groups, and the strain values were decreased in the HTx groups compared with the CG, with the global decreased change rates being 11%, 10%, 6%, and 8%, respectively.

Conclusions: The strain values decreased after HTx and almost remained stable in the long-time follow-ups. Compared with the CG in both ventricles, they were with preserved or reduced functions. In addition, the deformation values of the right ventricle decreased more than those of the left.

Citing Articles

Right Ventricular Function on Cardiovascular Magnetic Resonance Imaging and Long-Term Outcomes in Stable Heart Transplant Recipients.

Barrett C, Bawaskar P, Hughes A, Athwal P, Guo Y, Alexy T Circ Cardiovasc Imaging. 2024; 17(4):e016415.

PMID: 38563143 PMC: 11021158. DOI: 10.1161/CIRCIMAGING.123.016415.


Characterizing stenosis severity of coronary heart disease by myocardial work measurement in patients with preserved ejection fraction.

Ran H, Yao Y, Wan L, Ren J, Sheng Z, Zhang P Quant Imaging Med Surg. 2023; 13(8):5022-5033.

PMID: 37581060 PMC: 10423365. DOI: 10.21037/qims-22-955.


Serial changes of right ventricular function assessed by three-dimensional speckle-tracking echocardiography in clinically well adult heart transplantation patients.

Li M, Lv Q, Zhang Y, Sun W, Wu C, Zhang Y Int J Cardiovasc Imaging. 2022; 39(4):725-736.

PMID: 36543911 DOI: 10.1007/s10554-022-02778-7.


Myocardial Work Measurement With Functional Capacity Evaluation in Primary Systemic Hypertension Patients: Comparison Between Left Ventricle With and Without Hypertrophy.

Ran H, Ma X, Wan L, Ren J, Zhang J, Zhang P J Thorac Imaging. 2022; 39(3):137-145.

PMID: 36469699 PMC: 11027989. DOI: 10.1097/RTI.0000000000000690.


Evaluation of the myocardial deformation in the diagnosis of rejection after heart transplantation.

da Costa R, Tude Rodrigues A, Vieira M, Fischer C, Monaco C, Filho E Front Cardiovasc Med. 2022; 9:991016.

PMID: 36312230 PMC: 9606419. DOI: 10.3389/fcvm.2022.991016.