» Articles » PMID: 32021678

The Temporal Confounding Effects of Extra-cerebral Contamination Factors on the Hemodynamic Signal Measured by Functional Near-Infrared Spectroscopy

Overview
Date 2020 Feb 6
PMID 32021678
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Functional near-infrared spectroscopy (fNIRS) has been broadly applied for optical brain imaging. This method is hemodynamic-based functional brain imaging relying on the measurement of the neurovascular coupling to detect changes in cerebral neuronal activities. The extra-cerebral hemodynamic changes are important contaminating factors in fNIRS measurements. This error signal can be misinterpreted as cerebral activities during fNIRS studies. Recently, it was assumed that temporal changes in deoxygenated hemoglobin concentration [HHb] was hardly affected by superficial blood flow, and it was proposed that the activation maps could be determined from [HHb] at large source-detector separation. In the current study, we measured the temporal changes in [HHb] using a continueswave fNIRS device at large source-detector separation, while superficial blood flow was stimulated by infrared lasers. A mesh-based Monte Carlo code was applied to estimate fNIRS sensitivity to superficial hemodynamic changes in a realistic 3D MRI-based brain phantom. First, we simulated photon migration in a four-layered human-head slab model to calculate PPLs and fNIRS sensitivity. Then, the localization of the infrared laser inside a realistic brain model was studied using the Monte Carlo method. Finally, the changes in [HHb] over the prefrontal cortex of six adult males were measured by fNIRS at a source-detector separation of 3 cm. The results demonstrated that the relation between fNIRS sensitivity and an increase in S-D separation was nonlinear and a correlation between shallow and deep signals was observed. The presented results demonstrated that the temporal changes in the superficial blood flow could strongly affect HHb measurement at large source-detector separation. Hence, the cerebral activity map extracted from the [HHb] signal was mainly contaminated by superficial blood flow.

Citing Articles

The Influence of Extracerebral Tissue on Continuous Wave Near-Infrared Spectroscopy in Adults: A Systematic Review of In Vivo Studies.

Eleveld N, Esquivel-Franco D, Drost G, Absalom A, Zeebregts C, de Vries J J Clin Med. 2023; 12(8).

PMID: 37109113 PMC: 10146120. DOI: 10.3390/jcm12082776.


Evaluation of fNIRS signal components elicited by cognitive and hypercapnic stimuli.

Reddy P, Izzetoglu M, Shewokis P, Sangobowale M, Diaz-Arrastia R, Izzetoglu K Sci Rep. 2021; 11(1):23457.

PMID: 34873185 PMC: 8648757. DOI: 10.1038/s41598-021-02076-7.

References
1.
Kim M, Durduran T, Frangos S, Edlow B, Buckley E, Moss H . Noninvasive measurement of cerebral blood flow and blood oxygenation using near-infrared and diffuse correlation spectroscopies in critically brain-injured adults. Neurocrit Care. 2009; 12(2):173-80. PMC: 2844468. DOI: 10.1007/s12028-009-9305-x. View

2.
Drummond P, Lazaroo D . The effect of facial blood flow on ratings of blushing and negative affect during an embarrassing task: preliminary findings. J Anxiety Disord. 2012; 26(2):305-10. DOI: 10.1016/j.janxdis.2011.12.012. View

3.
Heinzel S, Haeussinger F, Hahn T, Ehlis A, Plichta M, Fallgatter A . Variability of (functional) hemodynamics as measured with simultaneous fNIRS and fMRI during intertemporal choice. Neuroimage. 2013; 71:125-34. DOI: 10.1016/j.neuroimage.2012.12.074. View

4.
Scholkmann F, Kleiser S, Metz A, Zimmermann R, Pavia J, Wolf U . A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology. Neuroimage. 2013; 85 Pt 1:6-27. DOI: 10.1016/j.neuroimage.2013.05.004. View

5.
Tachtsidis I, Scholkmann F . False positives and false negatives in functional near-infrared spectroscopy: issues, challenges, and the way forward. Neurophotonics. 2016; 3(3):031405. PMC: 4791590. DOI: 10.1117/1.NPh.3.3.031405. View