» Articles » PMID: 32014410

The Efficacy of Porous Hydroxyapatite Chips As Gap Filling in Open-wedge High Tibial Osteotomy in Terms of Clinical, Radiological, and Histological Criteria

Overview
Journal Knee
Publisher Elsevier
Specialty Orthopedics
Date 2020 Feb 5
PMID 32014410
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Hydroxyapatite (HA) does not fully degrade, which raises concerns about poor remodeling and incorporation into the bone after open-wedge high tibial osteotomy (HTO). The purpose of this study was to compare the results between gap filling with allogenous chip bone and HA chip after open-wedge HTO using propensity score matching and to analyze the radiological unabsorbed area of opening gaps histologically in HA using patients.

Methods: The matched variables were age, body mass index, sex, correction angle, and smoking status. After matching, the allogenous group and HA group included 33 patients each with two years of follow-up. The range of motion (ROM), International Knee Documentation Committee (IKDC) subjective score, Knee Injury and Osteoarthritis Outcome Score (KOOS), mechanical axis (MA), tibial slope, osteoconductivity, and absorbability were evaluated and compared between both groups. Among the HA group, 20 patients underwent bone biopsy and histologically analyzed of the radiological unabsorbed area.

Results: The postoperative ROM, IKDC subjective score, and KOOS were similar in both groups. The osteoconductivities did not differ significantly. The absorbability in the HA group was significantly lower than allogenous group (59.6% vs. 22.6%, P < .001). The histological sections of the radiological unabsorbed area showed mature lamelliform bone tissues were significantly greater than structurally degraded remnant HA (30.4% and 4.2%, P < .001).

Conclusion: The HA chips showed an inferior absorbability, however, a mature lamelliform bone was observed in significantly larger amounts than remnant HA in the radiological unabsorbed area. The allogenous bone chips and HA chips showed similar clinical and radiological results after open-wedge HTO.

Citing Articles

Radiographic Assessment of Bone Union in Proximal Tibia and Distal Femur Osteotomies: A Systematic Review.

Bax E, Harlianto N, Custers R, van Egmond N, Foppen W, Kruyt M JB JS Open Access. 2024; 9(4).

PMID: 39534655 PMC: 11557090. DOI: 10.2106/JBJS.OA.24.00101.


[Biomechanical study of three-dimensional printed filler block design in open wedge high tibial osteotomy].

Zhang J, Zhang J, Guo L, Chen S, Jin Z, Chen Z Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2024; 41(4):758-765.

PMID: 39218602 PMC: 11366453. DOI: 10.7507/1001-5515.202403056.


The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy.

Santoso A, Utomo P, Mahyudin F, Utomo D, Budhiparama N, Anwar I Ann Med Surg (Lond). 2023; 85(7):3339-3346.

PMID: 37427156 PMC: 10328623. DOI: 10.1097/MS9.0000000000000972.


In vivo Histological Examination of the Graft Site 3 Years after Open-wedge High Tibial Osteotomy with Nanohydroxyapatite Augmentation.

Princi G, Rossini M, Marzilli F, Di Niccolo R, Conteduca F, Ferretti A J Orthop Case Rep. 2022; 11(10):53-57.

PMID: 35415095 PMC: 8930291. DOI: 10.13107/jocr.2021.v11.i10.2466.


Effectiveness of bone substitute materials in opening wedge high tibial osteotomy: a systematic review and meta-analysis.

Bei T, Yang L, Huang Q, Wu J, Liu J Ann Med. 2022; 54(1):565-577.

PMID: 35166617 PMC: 8856078. DOI: 10.1080/07853890.2022.2036805.