A Low-Cost Breath Analyzer Module in Domiciliary Non-Invasive Mechanical Ventilation for Remote COPD Patient Monitoring

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Jan 30
PMID 31991608
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Smart Breath Analyzers were developed as sensing terminals of a telemedicine architecture devoted to remote monitoring of patients suffering from Chronic Obstructive Pulmonary Disease (COPD) and home-assisted by non-invasive mechanical ventilation via respiratory face mask. The devices based on different sensors (CO/O and Volatile Organic Compounds (VOCs), relative humidity and temperature (R.H. & T) sensors) monitor the breath air exhaled into the expiratory line of the bi-tube patient breathing circuit during a noninvasive ventilo-therapy session; the sensor raw signals are transmitted pseudonymized to National Health Service units by TCP/IP communication through a cloud remote platform. The work is a proof-of-concept of a sensors-based IoT system with the perspective to check continuously the effectiveness of therapy and/or any state of exacerbation of the disease requiring healthcare. Lab tests in controlled experimental conditions by a gas-mixing bench towards CO/O concentrations and exhaled breath collected in a sampling bag were carried out to test the realized prototypes. The Smart Breath Analyzers were also tested in real conditions both on a healthy volunteer subject and a COPD suffering patient.

Citing Articles

Pulmonary Magnetic Resonance Imaging Replaces Bedside Imaging in Diagnosing Pneumonia in Infants.

Zhang H, Zhang Y Biomed Res Int. 2022; 2022:7232638.

PMID: 36164449 PMC: 9509219. DOI: 10.1155/2022/7232638.


Breath Sensor Technology for the Use in Mechanical Lung Ventilation Equipment for Monitoring Critically Ill Patients.

Bhandari M, Veliks V, Stonans I, Padilla M, Suba O, Svare A Diagnostics (Basel). 2022; 12(2).

PMID: 35204521 PMC: 8870831. DOI: 10.3390/diagnostics12020430.


Volatile Gas Sensing through Terahertz Pipe Waveguide.

Lu J, You B, Wang J, Jhuo S, Hung T, Yu C Sensors (Basel). 2020; 20(21).

PMID: 33153176 PMC: 7662959. DOI: 10.3390/s20216268.

References
1.
Rabe K, Watz H . Chronic obstructive pulmonary disease. Lancet. 2017; 389(10082):1931-1940. DOI: 10.1016/S0140-6736(17)31222-9. View

2.
Domingo C, Blanch L, Murias G, Lujan M . State-of-the-art sensor technology in Spain: invasive and non-invasive techniques for monitoring respiratory variables. Sensors (Basel). 2012; 10(5):4655-74. PMC: 3292138. DOI: 10.3390/s100504655. View

3.
Murphy P, Hart N . Home Non-Invasive Ventilation for COPD: How, Who and When?. Arch Bronconeumol (Engl Ed). 2018; 54(3):149-154. DOI: 10.1016/j.arbres.2017.12.005. View

4.
Shigemura M, Lecuona E, Sznajder J . Effects of hypercapnia on the lung. J Physiol. 2017; 595(8):2431-2437. PMC: 5390878. DOI: 10.1113/JP273781. View

5.
Shafiek H, Fiorentino F, Merino J, Lopez C, Oliver A, Segura J . Using the Electronic Nose to Identify Airway Infection during COPD Exacerbations. PLoS One. 2015; 10(9):e0135199. PMC: 4564204. DOI: 10.1371/journal.pone.0135199. View