During image guided liver surgery, soft tissue deformation can cause considerable error when attempting to achieve accurate localization of the surgical anatomy through image-to-physical registration. In this paper, a linearized iterative boundary reconstruction technique is proposed to account for these deformations. The approach leverages a superposed formulation of boundary conditions to rapidly and accurately estimate the deformation applied to a preoperative model of the organ given sparse intraoperative data of surface and subsurface features. With this method, tracked intraoperative ultrasound (iUS) is investigated as a potential data source for augmenting registration accuracy beyond the capacity of conventional organ surface registration. In an expansive simulated dataset, features including vessel contours, vessel centerlines, and the posterior liver surface are extracted from iUS planes. Registration accuracy is compared across increasing data density to establish how iUS can be best employed to improve target registration error (TRE). From a baseline average TRE of 11.4 ± 2.2 mm using sparse surface data only, incorporating additional sparse features from three iUS planes improved average TRE to 6.4 ± 1.0 mm. Furthermore, increasing the sparse coverage to 16 tracked iUS planes improved average TRE to 3.9 ± 0.7 mm, exceeding the accuracy of registration based on complete surface data available with more cumbersome intraoperative CT without contrast. Additionally, the approach was applied to three clinical cases where on average error improved 67% over rigid registration and 56% over deformable surface registration when incorporating additional features from one independent tracked iUS plane.

Citing Articles

FEM simulation of breast deformation with semi-fluid representation.

Takahashi S, Fujimoto H, Nasu K, Nakaguchi T, Ienaga N, Kuroda Y Int J Comput Assist Radiol Surg. 2024; .

PMID: 39680267 DOI: 10.1007/s11548-024-03288-8.


A global sensitivity analysis of a mechanistic model of neoadjuvant chemotherapy for triple negative breast cancer constrained by in vitro and in vivo imaging data.

Lorenzo G, Jarrett A, Meyer C, DiCarlo J, Virostko J, Quaranta V Eng Comput. 2024; 40(3):1469-1499.

PMID: 39620056 PMC: 11607094. DOI: 10.1007/s00366-023-01873-0.


Deformable Mapping of Rectal Cancer Whole-Mount Histology with Restaging MRI at Voxel Scale: A Feasibility Study.

Miranda J, Heiselman J, Firat C, Chakraborty J, Vanguri R, Assuncao Jr A Radiol Imaging Cancer. 2024; 6(6):e240073.

PMID: 39452890 PMC: 11615632. DOI: 10.1148/rycan.240073.


Comparing regularized Kelvinlet functions and the finite element method for registration of medical images to sparse organ data.

Ringel M, Heiselman J, Richey W, Meszoely I, Jarnagin W, Miga M Med Image Anal. 2024; 96:103221.

PMID: 38824864 PMC: 11869944. DOI: 10.1016/j.media.2024.103221.


Comparison study of intraoperative surface acquisition methods on registration accuracy for soft-tissue surgical navigation.

Xiang B, Heiselman J, Richey W, DAngelica M, Wei A, Kingham T J Med Imaging (Bellingham). 2024; 11(2):025001.

PMID: 38445222 PMC: 10911768. DOI: 10.1117/1.JMI.11.2.025001.


References
1.
Kuiran Chen T, Thurston A, Ellis R, Abolmaesumi P . A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. Ultrasound Med Biol. 2008; 35(1):79-93. DOI: 10.1016/j.ultrasmedbio.2008.07.004. View

2.
Heiselman J, Clements L, Collins J, Weis J, Simpson A, Geevarghese S . Characterization and correction of intraoperative soft tissue deformation in image-guided laparoscopic liver surgery. J Med Imaging (Bellingham). 2017; 5(2):021203. PMC: 5729961. DOI: 10.1117/1.JMI.5.2.021203. View

3.
Simpson A, Geller D, Hemming A, Jarnagin W, Clements L, DAngelica M . Liver planning software accurately predicts postoperative liver volume and measures early regeneration. J Am Coll Surg. 2014; 219(2):199-207. PMC: 4128572. DOI: 10.1016/j.jamcollsurg.2014.02.027. View

4.
Plantefeve R, Peterlik I, Haouchine N, Cotin S . Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery. Ann Biomed Eng. 2015; 44(1):139-53. DOI: 10.1007/s10439-015-1419-z. View

5.
Lee D, Nam W, Lee J, Ra J . Non-rigid registration between 3D ultrasound and CT images of the liver based on intensity and gradient information. Phys Med Biol. 2010; 56(1):117-37. DOI: 10.1088/0031-9155/56/1/008. View