» Articles » PMID: 31881479

Does Fatigue Alter Step Characteristics and Stiffness During Running?

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2019 Dec 28
PMID 31881479
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Describing the response of spatiotemporal gait characteristics, and related variables such as variability and stiffness, to different stressors is important to better understand spring-mass model.

Research Question: This study aimed to examine the effect of fatigue induced by a running protocol on spatiotemporal gait parameters, step variability and vertical (Kvert) and leg stiffness (Kleg) during running on a treadmill.

Methods: Twenty-two trained male endurance runners performed a 60-min time trial run. An analysis of spatiotemporal parameters (contact time [CT], flight time [FT], step frequency [SF] and step length [SL]), step variability (in terms of coefficient of variation [CV]) and stiffness was conducted in two different conditions: non-fatigued (before the protocol) and fatigued (after the protocol).

Results: The pairwise comparisons (i.e., non-fatigued vs. fatigued condition) indicated that temporal parameters (i.e., CT and FT) experienced significant changes (p = 0.001 and <0.001, respectively). Step variability increased in presence of fatigue, with higher CV in CT (p = 0.039), FT (p = 0.005), SF (p = 0.046) and SL (p = 0.027) after the running protocol. The Kleg experienced a reduction in the fatigued condition (p < 0.001) whereas the Kvert remained unchanged (p = 0.602).

Significance: The results indicate that fatigue induced by a 60-min time trial run causes some adaptations in spatiotemporal gait characteristics and stiffness in trained endurance runners. Specifically, in the presence of fatigue, the athletes showed greater CT and shorter FT, higher step variability and lower leg stiffness.

Citing Articles

Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors.

Mason R, Celik Y, Barry G, Godfrey A, Stuart S Sensors (Basel). 2025; 25(1.

PMID: 39796819 PMC: 11723058. DOI: 10.3390/s25010030.


Wearable System Applications in Performance Analysis of RaceRunning Athletes with Disabilities.

Shafizadeh M, Davids K Sensors (Basel). 2025; 24(24.

PMID: 39771661 PMC: 11679408. DOI: 10.3390/s24247923.


Kinematical Effects of a Mandibular Advancement Occlusal Splint on Running until Exhaustion at Severe Intensity.

Cardoso F, Costa M, Rios M, Vilas-Boas J, Pinho J, Pyne D Sensors (Basel). 2024; 24(18).

PMID: 39338777 PMC: 11435913. DOI: 10.3390/s24186032.


Subject-specific sensitivity of several biomechanical features to fatigue during an exhaustive treadmill run.

Chalitsios C, Nikodelis T, Mavrommatis G, Kollias I Sci Rep. 2024; 14(1):1004.

PMID: 38200137 PMC: 10781943. DOI: 10.1038/s41598-024-51296-0.


The Influence of General and Local Muscle Fatigue on Kinematics and Plantar Pressure Distribution during Running: A Systematic Review and Meta-Analysis.

Hazzaa W, Hottenrott L, Kamal M, Mattes K Sports (Basel). 2023; 11(12).

PMID: 38133108 PMC: 10747919. DOI: 10.3390/sports11120241.